Your browser doesn't support javascript.
loading
Automated Atrial Fibrillation Detection Based on Feature Fusion Using Discriminant Canonical Correlation Analysis.
Shi, Jingjing; Chen, Chao; Liu, Hui; Wang, Yinglong; Shu, Minglei; Zhu, Qing.
Afiliação
  • Shi J; Shandong Artificial Intelligence Institute, Qilu University of Technology (Shandong Academy of Sciences), China.
  • Chen C; Shandong Artificial Intelligence Institute, Qilu University of Technology (Shandong Academy of Sciences), China.
  • Liu H; Shandong Artificial Intelligence Institute, Qilu University of Technology (Shandong Academy of Sciences), China.
  • Wang Y; Shandong Artificial Intelligence Institute, Qilu University of Technology (Shandong Academy of Sciences), China.
  • Shu M; Shandong Artificial Intelligence Institute, Qilu University of Technology (Shandong Academy of Sciences), China.
  • Zhu Q; Qilu Hospital of Shandong University, China.
Comput Math Methods Med ; 2021: 6691177, 2021.
Article em En | MEDLINE | ID: mdl-33897806
ABSTRACT
Atrial fibrillation (AF) is one of the most common cardiovascular diseases, with a high disability rate and mortality rate. The early detection and treatment of atrial fibrillation have great clinical significance. In this paper, a multiple feature fusion is proposed to screen out AF recordings from single lead short electrocardiogram (ECG) recordings. The proposed method uses discriminant canonical correlation analysis (DCCA) feature fusion. It fully takes intraclass correlation and interclass correlation into consideration and solves the problem of computation and information redundancy with simple series or parallel feature fusion. The DCCA integrates traditional features extracted by expert knowledge and deep learning features extracted by the residual network and gated recurrent unit network to improve the low accuracy of a single feature. Based on the Cardiology Challenge 2017 dataset, the experiments are designed to verify the effectiveness of the proposed algorithm. In the experiments, the F1 index can reach 88%. The accuracy, sensitivity, and specificity are 91.7%, 90.4%, and 93.2%, respectively.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Diagnóstico por Computador / Eletrocardiografia Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Revista: Comput Math Methods Med Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Diagnóstico por Computador / Eletrocardiografia Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Humans Idioma: En Revista: Comput Math Methods Med Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China