Your browser doesn't support javascript.
loading
Methodology for determination of radon prone areas combining the definition of a representative building enclosure and measurements of terrestrial gamma radiation.
Briones, C; Jubera, J; Alonso, H; Olaiz, J; Santana, J T; Rodríguez-Brito, N; Tejera, A; Martel, P; González-Díaz, E; Rubiano, J G.
Afiliação
  • Briones C; Dpto. de Técnicas y Proyectos en Ingeniería, y Arquitectura de la Universidad de La Laguna, 38204 Canary Islands, Spain.
  • Jubera J; Servicio de Laboratorios y Calidad de la Construcción del Gobierno de Canarias, 38107 Canary Islands, Spain.
  • Alonso H; Dpto. de Física, Universidad de Las Palmas de Gran Canaria, 35017 Canary Islands, Spain.
  • Olaiz J; Servicio de Laboratorios y Calidad de la Construcción del Gobierno de Canarias, 38107 Canary Islands, Spain.
  • Santana JT; Servicio de Laboratorios y Calidad de la Construcción del Gobierno de Canarias, 38107 Canary Islands, Spain.
  • Rodríguez-Brito N; Servicio de Laboratorios y Calidad de la Construcción del Gobierno de Canarias, 38107 Canary Islands, Spain.
  • Tejera A; Dpto. de Física, Universidad de Las Palmas de Gran Canaria, 35017 Canary Islands, Spain.
  • Martel P; Dpto. de Física, Universidad de Las Palmas de Gran Canaria, 35017 Canary Islands, Spain.
  • González-Díaz E; Dpto. de Técnicas y Proyectos en Ingeniería, y Arquitectura de la Universidad de La Laguna, 38204 Canary Islands, Spain.
  • Rubiano JG; Dpto. de Física, Universidad de Las Palmas de Gran Canaria, 35017 Canary Islands, Spain. Electronic address: jesus.garciarubiano@ulpgc.es.
Sci Total Environ ; 788: 147709, 2021 Sep 20.
Article em En | MEDLINE | ID: mdl-34029827
ABSTRACT
The recommendations of the European Atomic Energy Community (EURATOM) have recently been incorporated into Spanish regulations in the Basic Document of Health Standards of the Technical Building Code (CTE), section HS6, on protection against radon exposure. This further accentuates the need to delimit radon prone areas as a strategy to address measures which minimise the effects of this gas on the population. In this research, measurements of terrestrial gamma radiation and indoor radon of dwellings have been carried out in the same location to delimit these risk areas. A new methodology has been developed including a definition of a Representative Building Enclosure (RBE) and it is proposed a Building Storey Index (IBS) which allows normalizing measurements of indoor radon activity concentration taken in different levels from the ground to the RBE. The results show the need to consider the type of contact that exists between the building and the ground as a determining factor of radon risk. Terrestrial gamma radiation is used as a proxy for radioisotopic composition of soils to characterise the indoor radon risk at different geological formation.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Sci Total Environ Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Sci Total Environ Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Espanha