The Standard Point-of-Care Hemochron Jr. ACT+ Test in Monitoring Heparin Administration for Cardiopulmonary Bypass in Severe Factor XII Deficiency.
Erkinaro, Tiina; Moilanen, Janne; Lahtinen, Jarmo; Mosorin, Martti; Savolainen, Eeva-Riitta.
Afiliação
  • Erkinaro T; Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Finland. Electronic address: tiina.erkinaro@oulu.fi.
  • Moilanen J; Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Finland.
  • Lahtinen J; Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Finland.
  • Mosorin M; Research Group of Surgery, Anesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Finland.
  • Savolainen ER; Nordlab Oulu Hematology Laboratory, Medical Research Center Oulu, Oulu University Hospital, University of Oulu, Finland.
J Cardiothorac Vasc Anesth ; 36(7): 2031-2034, 2022 07.
Article em En | MEDLINE | ID: mdl-34130893
Coagulation factor XII (FXII) is a plasma serine protease that belongs to the contact activation complex responsible for initiating the intrinsic coagulation pathway. FXII deficiency is a rare congenital disorder that is not associated with an increased tendency for bleeding. However, as contact activation is impaired in FXII deficiency, both the celite- and kaolin-initiated activated clotting time (ACT) measurements are prolonged markedly, which poses a challenge for anticoagulation monitoring in patients undergoing cardiac surgery. The authors successfully have used the standard Hemochron Jr. ACT+ test, which is activated by silica and phospholipid in addition to kaolin, to monitor anticoagulation for cardiopulmonary bypass in two patients with severe FXII deficiency. The ACT+ test showed low baseline values, increased adequately in response to heparin, and decreased to baseline after protamine. Importantly, there was no abnormal intra- or postoperative bleeding nor any thrombotic complications. Furthermore, in vitro dose-response ACT+ testing of FXII-deficient blood with increasing heparin concentrations supports the use of ACT+ in FXII deficiency.