Your browser doesn't support javascript.
loading
Modified Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Prostate: Comparison With Reduced Field-of-View Imaging and Single Shot Echo-Planar Imaging.
Lee, Eun Ji; Hwang, Jiyoung; Chang, Yun-Woo; Hong, Seong Sook; Oh, Eunsun; Nam, Bo Da; Sung, Jae Kon; Thomas, Benkert.
Afiliação
  • Lee EJ; From the Department of Radiology, Soonchunhyang University Seoul Hospital.
  • Hwang J; From the Department of Radiology, Soonchunhyang University Seoul Hospital.
  • Chang YW; From the Department of Radiology, Soonchunhyang University Seoul Hospital.
  • Hong SS; From the Department of Radiology, Soonchunhyang University Seoul Hospital.
  • Oh E; From the Department of Radiology, Soonchunhyang University Seoul Hospital.
  • Nam BD; From the Department of Radiology, Soonchunhyang University Seoul Hospital.
  • Sung JK; Siemens Healthineers Ltd, Seoul, Korea.
  • Thomas B; Siemens Healthcare GmbH, Erlangen, Germany.
J Comput Assist Tomogr ; 45(3): 367-373, 2021.
Article em En | MEDLINE | ID: mdl-34297508
OBJECTIVE: The objective of this study was to compare the image quality and apparent diffusion coefficient (ADC) of diffusion-weighted imaging (DWI) with modified reduced field of view (FOV) based on 2-dimensional (2D)-selective radiofrequency excitations by tilting the excitation plane in prostate with reduced FOV using parallel-transmit-accelerated 2D-selective radiofrequency excitation and single-shot echo planar imaging (ssEPI). METHODS: Fifty patients who underwent multiparametric magnetic resonance imaging including 3 DWIs were included. Two observers independently performed qualitative image analyses using 5-point scale. Apparent diffusion coefficient measurements were performed for quantitative analysis. RESULTS: Modified reduced FOV provided the highest qualitative scores for all categories compared with reduced FOV and ssEPI (P < 0.000). Both reduced FOV DWIs showed higher ADC values compared with ssEPI (P < 0.001); however, the ADC ratios between the lesion and peripheral zone were not significantly different (all P > 0.05). CONCLUSIONS: The modified reduced FOV DWI showed better overall image quality, differentiability of anatomic regions, and lesion conspicuity with fewer artifacts compared with DWI with reduced FOV and ssEPI.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Próstata / Interpretação de Imagem Radiográfica Assistida por Computador / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Observational_studies / Qualitative_research Limite: Adult / Aged / Aged80 / Humans / Male / Middle aged Idioma: En Revista: J Comput Assist Tomogr Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Próstata / Interpretação de Imagem Radiográfica Assistida por Computador / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Observational_studies / Qualitative_research Limite: Adult / Aged / Aged80 / Humans / Male / Middle aged Idioma: En Revista: J Comput Assist Tomogr Ano de publicação: 2021 Tipo de documento: Article