Your browser doesn't support javascript.
loading
Dosimetric effects of quality assurance-related setup errors in passive proton therapy for prostate cancer with and without a hydrogel spacer.
Omi, Yuta; Yasui, Keisuke; Shimomura, Akira; Muramatsu, Rie; Iwata, Hiromitsu; Ogino, Hiroyuki; Furukawa, Akari; Hayashi, Naoki.
Afiliação
  • Omi Y; Anjo Kosei Hospital, 28 Higashi-Hirokute, Anjo-cho, Anjo, Aichi, 446-8602, Japan.
  • Yasui K; Faculty of Radiological Technology, School of Health Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan. k-yasui@fujita-hu.ac.jp.
  • Shimomura A; Nagoya Proton Therapy Center, Nagoya City West Medical Center, 1-1-1, Hirate-cho, Kita-ku, Nagoya, Aichi, 462-8508, Japan.
  • Muramatsu R; Nagoya Proton Therapy Center, Nagoya City West Medical Center, 1-1-1, Hirate-cho, Kita-ku, Nagoya, Aichi, 462-8508, Japan.
  • Iwata H; Nagoya Proton Therapy Center, Nagoya City West Medical Center, 1-1-1, Hirate-cho, Kita-ku, Nagoya, Aichi, 462-8508, Japan.
  • Ogino H; Nagoya Proton Therapy Center, Nagoya City West Medical Center, 1-1-1, Hirate-cho, Kita-ku, Nagoya, Aichi, 462-8508, Japan.
  • Furukawa A; Faculty of Radiological Technology, School of Health Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan.
  • Hayashi N; Faculty of Radiological Technology, School of Health Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan.
Radiol Phys Technol ; 14(3): 328-335, 2021 Sep.
Article em En | MEDLINE | ID: mdl-34313911
ABSTRACT
The purpose of this study was to evaluate the effect of quality assurance (QA)-related setup errors in passive proton therapy for prostate cancer with and without a hydrogel spacer. We used 20 typical computed tomography (CT) images of prostate cancer 10 patients with and 10 patients without spacers. The following 12 model errors were assumed output error ± 2%, range error ± 1 mm, setup error ± 1 mm for three directions, and multileaf collimator (MLC) position error ± 1 mm. We created verification plans with model errors and compared the prostate-rectal (PR) distance and dose indices with and without the spacer. The mean PR distance at the isocenter was 1.1 ± 1.3 mm without the spacer and 12.9 ± 2.9 mm with the spacer (P < 0.001). The mean rectum V53.5 GyE, V50 GyE, and V34.5 GyE in the original plan were 2.3%, 4.1%, and 12.1% without the spacer and 0.1%, 0.4%, and 3.3% with the spacer (P = 0.0011, < 0.001, and < 0.001). The effects of the range and lateral setup errors were small; however, the effects of the vertical/long setup and MLC error were significant in the cases without the spacer. The means of the maximum absolute change from original plans across all scenarios in the rectum V53.5 GyE, V50 GyE, and V34.5 GyE were 1.3%, 1.5%, and 2.3% without the spacer, and 0.2%, 0.4%, and 1.3% with the spacer (P < 0.001, < 0.001, and = 0.0019). This study indicated that spacer injections were also effective in reducing the change in the rectal dose due to setup errors.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Radioterapia de Intensidade Modulada / Terapia com Prótons Limite: Humans / Male Idioma: En Revista: Radiol Phys Technol Assunto da revista: BIOFISICA / RADIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Radioterapia de Intensidade Modulada / Terapia com Prótons Limite: Humans / Male Idioma: En Revista: Radiol Phys Technol Assunto da revista: BIOFISICA / RADIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Japão