Your browser doesn't support javascript.
loading
Device interaction between cardiac contractility modulation (CCM) and subcutaneous defibrillator (S-ICD).
Trolese, Luca; Faber, Thomas; Gressler, Alexander; Steinfurt, Johannes; Stuplich, Judith; Jordan, Eike; Bode, Christoph; Zehender, Manfred; Hilgendorf, Ingo.
Afiliação
  • Trolese L; Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Faber T; Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Gressler A; Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Steinfurt J; Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Stuplich J; Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Jordan E; Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Bode C; Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Zehender M; Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Hilgendorf I; Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
J Cardiovasc Electrophysiol ; 32(11): 3095-3098, 2021 11.
Article em En | MEDLINE | ID: mdl-34379359
Combined implantation of cardiac contractility modulation (CCM) with subcutaneous implantable cardioverter-defibrillator (S-ICD) appears a suitable option to reduce the amount of intracardiac leads and complications for patients. Here we report on a patient with ischemic cardiomyopathy carrying an S-ICD in which a CCM device was implanted. During crosstalk testing post-CCM implantation, the S-ICD misannotated QRS complexes and T waves. The problem was solved through reprogramming the CCM, while preserving S-ICD functionality and improving heart failure symptoms. In conclusion, S-ICD combined with CCM seems to be a good and safe option for patients when device interference is being ruled out.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Desfibriladores Implantáveis / Eletrocardiografia Limite: Humans Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Desfibriladores Implantáveis / Eletrocardiografia Limite: Humans Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Alemanha