Your browser doesn't support javascript.
loading
Optical emission-based phantom to verify coincidence of radiotherapy and imaging isocenters on an MR-linac.
Andreozzi, Jacqueline M; Bruza, Petr; Cammin, Jochen; Alexander, Daniel A; Pogue, Brian W; Green, Olga; Gladstone, David J.
Afiliação
  • Andreozzi JM; Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
  • Bruza P; Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida, USA.
  • Cammin J; Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
  • Alexander DA; Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA.
  • Pogue BW; Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
  • Green O; Thayer School of Engineering and Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire, USA.
  • Gladstone DJ; Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri, USA.
J Appl Clin Med Phys ; 22(9): 252-261, 2021 Sep.
Article em En | MEDLINE | ID: mdl-34409766
ABSTRACT

PURPOSE:

Demonstrate a novel phantom design using a remote camera imaging method capable of concurrently measuring the position of the x-ray isocenter and the magnetic resonance imaging (MRI) isocenter on an MR-linac.

METHODS:

A conical frustum with distinct geometric features was machined out of plastic. The phantom was submerged in a small water tank, and aligned using room lasers on a MRIdian MR-linac (ViewRay Inc., Cleveland, OH). The phantom physical isocenter was visualized in the MR images and related to the DICOM coordinate isocenter. To view the x-ray isocenter, an intensified CMOS camera system (DoseOptics LLC., Hanover, NH) was placed at the foot of the treatment couch, and centered such that the optical axis of the camera was coincident with the central axis of the treatment bore. Two or four 8.3mm x 24.1cm beams irradiated the phantom from cardinal directions, producing an optical ring on the conical surface of the phantom. The diameter of the ring, measured at the peak intensity, was compared to the known diameter at the position of irradiation to determine the Z-direction offset of the beam. A star-shot method was employed on the front face of the frustum to determine X-Y alignment of the MV beam. Known shifts were applied to the phantom to establish the sensitivity of the method.

RESULTS:

Couch translations, demonstrative of possible isocenter misalignments, on the order of 1mm were detectable for both the radiotherapy and MRI isocenters. Data acquired on the MR-linac demonstrated an average error of 0.28mm(N=10, R2 =0.997, σ=0.37mm) in established Z displacement, and 0.10mm(N=5, σ=0.34mm) in XY directions of the radiotherapy isocenter.

CONCLUSIONS:

The phantom was capable of measuring both the MRI and radiotherapy treatment isocenters. This method has the potential to be of use in MR-linac commissioning, and could be streamlined to be valuable in daily constancy checks of isocenter coincidence.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aceleradores de Partículas / Radioterapia Guiada por Imagem Limite: Humans Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aceleradores de Partículas / Radioterapia Guiada por Imagem Limite: Humans Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos