Your browser doesn't support javascript.
loading
Validation of a novel system to assess end-expiratory lung volume and alveolar recruitment in an ARDS model.
Bitker, Laurent; Carvalho, Nadja Cristinne; Reidt, Sascha; Schranz, Christoph; Novotni, Dominik; Orkisz, Maciej; Davila Serrano, Eduardo; Revelly, Jean-Pierre; Richard, Jean-Christophe.
Afiliação
  • Bitker L; Service de Médecine Intensive - Réanimation, Hôpital De La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004, Lyon, France.
  • Carvalho NC; Université de Lyon, Université Claude Bernard Lyon 1, INSA-Lyon, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France.
  • Reidt S; Research and New Technology Department, Hamilton Medical AG, Bonaduz, Switzerland.
  • Schranz C; Research and New Technology Department, Hamilton Medical AG, Bonaduz, Switzerland.
  • Novotni D; Research and New Technology Department, Hamilton Medical AG, Bonaduz, Switzerland.
  • Orkisz M; Research and New Technology Department, Hamilton Medical AG, Bonaduz, Switzerland.
  • Davila Serrano E; Université de Lyon, Université Claude Bernard Lyon 1, INSA-Lyon, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France.
  • Revelly JP; Université de Lyon, Université Claude Bernard Lyon 1, INSA-Lyon, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France.
  • Richard JC; Research and New Technology Department, Hamilton Medical AG, Bonaduz, Switzerland.
Intensive Care Med Exp ; 9(1): 46, 2021 Sep 10.
Article em En | MEDLINE | ID: mdl-34505190
BACKGROUND: Personalizing mechanical ventilation requires the development of reliable bedside monitoring techniques. The multiple-breaths nitrogen washin-washout (MBNW) technique is currently available to measure end-expiratory lung volume (EELVMBNW), but the precision of the technique may be poor, with percentage errors ranging from 28 to 57%. The primary aim of the study was to evaluate the reliability of a novel MBNW bedside system using fast mainstream sensors to assess EELV in an experimental acute respiratory distress syndrome (ARDS) model, using computed tomography (CT) as the gold standard. The secondary aims of the study were: (1) to evaluate trending ability of the novel system to assess EELV; (2) to evaluate the reliability of estimated alveolar recruitment induced by positive end-expiratory pressure (PEEP) changes computed from EELVMBNW, using CT as the gold standard. RESULTS: Seven pigs were studied in 6 experimental conditions: at baseline, after experimental ARDS and during a decremental PEEP trial at PEEP 16, 12, 6 and 2 cmH2O. EELV was computed at each PEEP step by both the MBNW technique (EELVMBNW) and CT (EELVCT). Repeatability was assessed by performing replicate measurements. Alveolar recruitment between two consecutive PEEP levels after lung injury was measured with CT (VrecCT), and computed from EELV measurements (VrecMBNW) as ΔEELV minus the product of ΔPEEP by static compliance. EELVMBNW and EELVCT were significantly correlated (R2 = 0.97). An acceptable non-constant bias between methods was identified, slightly decreasing toward more negative values as EELV increased. The conversion equation between EELVMBNW and EELVCT was: EELVMBNW = 0.92 × EELVCT + 36. The 95% prediction interval of the bias amounted to ± 86 mL and the percentage error between both methods amounted to 13.7%. The median least significant change between repeated measurements amounted to 8% [CI95%: 4-10%]. EELVMBNW adequately tracked EELVCT changes over time (concordance rate amounting to 100% [CI95%: 87%-100%] and angular bias amounting to - 2° ± 10°). VrecMBNW and VrecCT were significantly correlated (R2 = 0.92). A non-constant bias between methods was identified, slightly increasing toward more positive values as Vrec increased. CONCLUSIONS: We report a new bedside MBNW technique that reliably assesses EELV in an experimental ARDS model with high precision and excellent trending ability.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Intensive Care Med Exp Ano de publicação: 2021 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Intensive Care Med Exp Ano de publicação: 2021 Tipo de documento: Article País de afiliação: França