Your browser doesn't support javascript.
loading
UVPD spectroscopy of differential mobility-selected prototropic isomers of protonated adenine.
Heldmaier, Fiorella Villanueva; Coughlan, Neville J A; Haack, Alexander; Huard, Rebecca; Guna, Mircea; Schneider, Bradley B; Le Blanc, J C Yves; Campbell, J Larry; Nooijen, Marcel; Hopkins, W Scott.
Afiliação
  • Heldmaier FV; Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada. shopkins@uwaterloo.ca.
  • Coughlan NJA; Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada.
  • Haack A; Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada. shopkins@uwaterloo.ca.
  • Huard R; Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada.
  • Guna M; Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada. shopkins@uwaterloo.ca.
  • Schneider BB; Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada.
  • Le Blanc JCY; Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada. shopkins@uwaterloo.ca.
  • Campbell JL; Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada.
  • Nooijen M; SCIEX, Four Valley Drive, Concord, Ontario, L4K 4V8, Canada.
  • Hopkins WS; SCIEX, Four Valley Drive, Concord, Ontario, L4K 4V8, Canada.
Phys Chem Chem Phys ; 23(35): 19892-19900, 2021 Sep 15.
Article em En | MEDLINE | ID: mdl-34525152
Two prototropic isomers of adenine are formed in an electrospray ion source and are resolved spatially in a differential mobility spectrometer before detection in a triple quadrupole mass spectrometer. Each isomer is gated in CV space before being trapped in the linear ion trap of the modified mass spectrometer, where they are irradiated by the tuneable output of an optical parametric oscillator and undergo photodissociation to form charged fragments with m/z 119, 109, and 94. The photon-normalised intensity of each fragmentation channel is measured and the action spectra for each DMS-gated tautomer are obtained. Our analysis of the action spectra, aided by calculated vibronic spectra and thermochemical data, allow us to assign the two signals in our measured ionograms to specific tautomers of protonated adenine.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrofotometria Infravermelho / Adenina Idioma: En Revista: Phys Chem Chem Phys Assunto da revista: BIOFISICA / QUIMICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrofotometria Infravermelho / Adenina Idioma: En Revista: Phys Chem Chem Phys Assunto da revista: BIOFISICA / QUIMICA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Canadá