Your browser doesn't support javascript.
loading
Polyetheretherketone versus titanium CAD-CAM framework for implant-supported fixed complete dentures: a retrospective study with up to 5-year follow-up.
Wang, Jing; Wu, Peng; Liu, Hai-Lin; Zhang, Ling; Liu, Li-Peng; Ma, Chu-Fan; Chen, Ji-Hua.
Afiliação
  • Wang J; National Clinical Research Center for Oral Diseases and State Key Laboratory of Military Stomatology and Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China.
  • Wu P; Key Laboratory of Shaanxi Province for Craniofacial Precision Medical Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, China.
  • Liu HL; Department of Stomatology, Peking University People's Hospital, Beijing, China.
  • Zhang L; Ruica Dental Lab., Beijing, China.
  • Liu LP; National Clinical Research Center for Oral Diseases and State Key Laboratory of Military Stomatology and Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China.
  • Ma CF; National Clinical Research Center for Oral Diseases and State Key Laboratory of Military Stomatology and Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China.
  • Chen JH; National Clinical Research Center for Oral Diseases and State Key Laboratory of Military Stomatology and Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China.
J Prosthodont Res ; 66(2): 279-287, 2022 Apr 27.
Article em En | MEDLINE | ID: mdl-34588401
ABSTRACT

PURPOSE:

To evaluate the performance of polyetheretherketone (PEEK) versus titanium computer-aided designed and manufactured (CAD-CAM) framework for implant-supported fixed complete dentures (ISFCDs) with a follow-up for a duration of up to 5 years.

METHODS:

Consecutively edentulous patients who underwent ISFCDs with a PEEK framework or titanium framework at one dental specialist center were included in this retrospective study. Implant/prosthesis survival rates, mechanical/biological complications, and bone and soft tissue parameters were analyzed. Overall survival was analyzed using Kaplan-Meier survival curves and the log-rank test.

RESULTS:

Sixty ISFCDs (29 PEEK, 31 titanium) performed on 43 edentulous patients (331 implants) were included. An implant survival rate of 100% was obtained. There was no significant difference in the cumulative prosthesis survival rate between the PEEK (93.1%) and titanium groups (93.5%). The most common mechanical complications were fracture of the artificial veneer in both the PEEK (13.8%) and titanium (16.7%) groups. Bruxers had a higher prevalence of mechanical complications than non-bruxers (p<0.05). The biological complications included bleeding upon probing (13.8% for the PEEK group; 16.1% for the titanium group), soft tissue inflammation (3.4% for the PEEK group; 3.2% for the titanium group), and temporomandibular disorders (6.5% for the titanium group). The vertical bone loss was significantly lower in the PEEK group (0.70 mm) than in the titanium group (0.96 mm). Smokers had a significantly higher prevalence of biological complications than non-smokers.

CONCLUSION:

Within the limitations of this study, ISFCDs with PEEK frameworks can provide good prognosis for edentulous patients, still requiring longer-term validation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Titânio / Implantes Dentários Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Prosthodont Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Titânio / Implantes Dentários Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Prosthodont Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China