Evaluation of the feasibility of acetabular cup pre-determination in revision total hip arthroplasty via X-ray of the bone stock of the anterosuperior acetabulum.
Zhang, Jingwei; Kong, Keyu; Chi, Yingjun; Liu, Xiaoliang; Zeng, Yiming; Li, Huiwu.
Afiliação
  • Zhang J; Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China.
  • Kong K; Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China.
  • Chi Y; Department of Orthopedics, Shengzhou People's Hospital (the First Affiliated Hospital of Zhejiang University Shengzhou Branch), No.666, Dangui Road, Shengzhou, 312400, Zhejiang, People's Republic of China.
  • Liu X; Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China.
  • Zeng Y; Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China. huiwu1223@163.com.
  • Li H; Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China. xyhz29@163.com.
J Orthop Surg Res ; 16(1): 597, 2021 Oct 14.
Article em En | MEDLINE | ID: mdl-34649561
ABSTRACT

PURPOSE:

This study was aimed to explore (1) location on AP pelvic X-ray that displayed bone stock in anterosuperior acetabulum; (2) whether X-ray could provide enough evidence to evaluate whether bone stock could provide support for acetabular cup; (3) criteria to determine whether anterosuperior bone stock could provide sufficient support for cup on X-ray.

METHODS:

Our study retrospectively collected 43 patients who underwent revision THA for cup loosening from 2014 to 2019. The position of anterosuperior acetabular bone stock was compared between X-ray and CT-based 3-D reconstruction. Seventy-millimeter acetabular cup was implanted simulatively to obtain the contact line between acetabular cup and superolateral remaining bone stock. The contact line length and the angle were measured. Patients were divided into cup group and cage group, and ROC curves of both contact line length and angle were drawn.

RESULTS:

The superolateral part of acetabulum on X-ray could reflect the anterosuperior host bone stock of acetabulum according to the comparison of anteroposterior pelvic X-ray and 3-D reconstruction. Critical point was chosen when we got the highest sensitivity with a 100% specificity in ROC curves. The critical values of contact length and angle were 15.58 mm and 25.5°.

CONCLUSIONS:

Surgeons could assess the anterosuperior bone stock of acetabulum by AP pelvic X-ray to decide whether revision could be done merely using cup or need customized cage. Clinically, when contact line length was larger than 16 mm or contact angle was larger than 25.5°, adoption of cup could obtain primary stability in the revision surgery in most cases.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril / Acetábulo Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: J Orthop Surg Res Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril / Acetábulo Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: J Orthop Surg Res Ano de publicação: 2021 Tipo de documento: Article