Your browser doesn't support javascript.
loading
Highly Sensitive Voltammetric Determination of Acrylamide Based on Ibuprofen Capped Mercury Nanoparticles.
Tagar, Zulfiqar Ali; Ul Haq, Muhammad Anwar; Shah, Muhammad Raza; Sherazi, Syed Tufail Hussain; Barek, Jiri; Kalhoro, Muhammad Siddique.
Afiliação
  • Sirajuddin; International Center for Chemical and Biological Sciences, HEJ Research Institute of Chemistry, University of Karachi, Karachi 75270, Pakistan.
  • Tagar ZA; National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan.
  • Ul Haq MA; International Center for Chemical and Biological Sciences, HEJ Research Institute of Chemistry, University of Karachi, Karachi 75270, Pakistan.
  • Shah MR; International Center for Chemical and Biological Sciences, HEJ Research Institute of Chemistry, University of Karachi, Karachi 75270, Pakistan.
  • Mujeeb-Ur-Rehman; International Center for Chemical and Biological Sciences, HEJ Research Institute of Chemistry, University of Karachi, Karachi 75270, Pakistan.
  • Sherazi STH; National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan.
  • Barek J; UNESCO Laboratory of Environmental Electrochemistry, Department of Analytical Chemistry, Faculty of Science, Charles University, Albertov 6, CZ-15843 Prague, Czech Republic.
  • Kalhoro MS; Institute of Physics, University of Sindh, Jamshoro 76080, Pakistan.
Sensors (Basel) ; 21(21)2021 Nov 02.
Article em En | MEDLINE | ID: mdl-34770608
ABSTRACT
Highly stable, small-sized and evenly distributed solid mercury nanoparticles capped with ibuprofen (Ibu-HgNPs) were prepared via reduction with hydrazine and capped with ibuprofen as a stabilizing agent. Characterization of Ibu-HgNPs was carried out by UV-Vis spectrophotometry and transmission electron microscopy (TEM). The prepared Ibu-HgNPs were immobilized onto a glassy carbon electrode (GCE) and used for the first time as the sensing element for voltammetric determination of low concentrations of acrylamide (AA) in aqueous solutions. Various parameters such as the type of supporting electrolyte, voltammetric mode, frequency, deposition time, stirring rate and initial potential were optimized to obtain the highest peak current of AA. The sensor delivered the best results in combination with the square wave voltammetry (SWV) mode, with good repeatability (relative standard deviation (RSD) of 25 repetitions was 1.4% for 1000 ppb AA). The study further revealed that Ibu-HgNPs are strongly adhered to GCE and hence do not contaminate the environment even after several runs. The newly developed AA sensor provides linear calibration dependence in the range of 100-1300 ppb with an R2 value of 0.996 and limit of detection (LOD) of 8.5 ppb. Negligible interference was confirmed from several organic compounds, cations and anions. The developed sensor was successfully applied for AA determination in various types of environmental real water samples to prove its practical usefulness and applicability.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nanopartículas / Mercúrio Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Paquistão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nanopartículas / Mercúrio Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Paquistão