Your browser doesn't support javascript.
loading
HPLC Analysis of the Urinary Iodine Concentration in Pregnant Women.
Mikulska, Aniceta A; Filipowicz, Dorota; Glówka, Franciszek K; Szczepanek-Parulska, Ewelina; Ruchala, Marek; Bartecki, Michal; Karazniewicz-Lada, Marta.
Afiliação
  • Mikulska AA; Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, 60-781 Poznan, Poland.
  • Filipowicz D; Department of Endocrinology, Metabolism and Internal Medicine, Poznan University of Medical Sciences, 60-356 Poznan, Poland.
  • Glówka FK; Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, 60-781 Poznan, Poland.
  • Szczepanek-Parulska E; Department of Endocrinology, Metabolism and Internal Medicine, Poznan University of Medical Sciences, 60-356 Poznan, Poland.
  • Ruchala M; Department of Endocrinology, Metabolism and Internal Medicine, Poznan University of Medical Sciences, 60-356 Poznan, Poland.
  • Bartecki M; Department of Pediatric Cardiology, Poznan University of Medical Science, 60-572 Poznan, Poland.
  • Karazniewicz-Lada M; Department of Physical Pharmacy and Pharmacokinetics, Poznan University of Medical Sciences, 60-781 Poznan, Poland.
Molecules ; 26(22)2021 Nov 10.
Article em En | MEDLINE | ID: mdl-34833891
ABSTRACT
Iodine is an essential component for fetal neurodevelopment and maternal thyroid function. Urine iodine is the most widely used indicator of iodine status. In this study, a novel validated ion-pair HPLC-UV method was developed to measure iodine concentration in clinical samples. A sodium thiosulfate solution was added to the urine sample to convert the total free iodine to iodide. Chromatographic separation was achieved in a Pursuit XRs C8 column. The mobile phase consisted of acetonitrile and a water phase containing 18-crown-6-ether, octylamine and sodium dihydrogen phosphate. Validation parameters, such as accuracy, precision, limits of detection and quantification, linearity and stability, were determined. Urinary samples from pregnant women were used to complete the validation and confirm the method's applicability. In the studied population of 93 pregnant women, the median UIC was lower in the group without iodine supplementation (117 µg/L, confidence interval (%CI) 95; 138) than in the supplement group (133 µg/L, %CI 109; 157). In conclusion, the newly established ion-pair HPLC-UV method was adequately precise, accurate and fulfilled validation the criteria for analyzing compounds in biological fluids. The method is less complicated and expensive than other frequently used assays and permits the identification of the iodine-deficient subjects.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Iodo Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Middle aged / Pregnancy País/Região como assunto: Europa Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Iodo Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Middle aged / Pregnancy País/Região como assunto: Europa Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Polônia