Your browser doesn't support javascript.
loading
Leg length measures appear inaccurate in the early phase following total hip arthroplasty.
Smolle, Maria Anna; Fischerauer, Stefan Franz; Maier, Michael; Reinbacher, Patrick; Friesenbichler, Jörg; Ruckenstuhl, Paul; Grandesso, Maria; Leithner, Andreas; Maurer-Ertl, Werner.
Afiliação
  • Smolle MA; Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
  • Fischerauer SF; Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria. stefan.fischerauer@medunigraz.at.
  • Maier M; Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
  • Reinbacher P; Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
  • Friesenbichler J; Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
  • Ruckenstuhl P; Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
  • Grandesso M; Dipartimento Universitario Clinico Di Scienze Mediche, Chirurgiche E Della Salute, Universitá Degli Studi Di Trieste, Strada Di Fiume, 447, Trieste, Italy.
  • Leithner A; Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
  • Maurer-Ertl W; Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
Sci Rep ; 11(1): 23262, 2021 12 01.
Article em En | MEDLINE | ID: mdl-34853409
The aims of this study were to (1) assess reliability of leg length discrepancy (LLD) measurements at different anatomical landmarks, (2) longitudinally investigate LLD in patients within the first year following total hip arthroplasty (THA) and to (3) correlate changes in LLD with functional outcome. Ninety-nine patients with short stem THA (53.3% males, mean age: 61.0 ± 8.1 years) were prospectively included. Upright pelvic anteroposterior (a.p.) radiographs taken at 6 timepoints (preoperatively, discharge, 6, 12, 24, 52 weeks postoperatively) were used to assess LLD at 5 anatomical landmarks (iliac crest, upper sacroiliac joint, lower sacroiliac joint, tear drop figure, greater trochanter). WOMAC and Harris Hip Score (HHS) were obtained preoperatively and at 6 and 52 weeks. LLD measures significantly increased in the initial phase following THA, from discharge to 6 weeks postoperatively and remained constant thereafter. Documentation of LLDs is dependent on measurement site: LLDs varied significantly between trochanter and iliac crest to tear drop figure (p < 0.001). Functional assessments did not correlate with the occurrence of LLDs [WOMAC (p = 0.252); HHS (p = 0.798)]. Radiographic assessment of LLD following THA may not be performed early postoperatively, as measurements appear to inaccurately reflect actual LLDs at this time, potentially due incomplete leg extension and/or inhibited weight-bearing.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiografia / Artroplastia de Quadril / Perna (Membro) Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Áustria

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiografia / Artroplastia de Quadril / Perna (Membro) Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Áustria