Your browser doesn't support javascript.
loading
Removal of Electrophysiological Devices in the Context of Heart Transplantation: Comparison of Combined and Staged Extraction Procedures.
Immohr, Moritz Benjamin; Boeken, Udo; Smiris, Konstantinos; Erbel-Khurtsidze, Sophiko; Oehler, Daniel; Dalyanoglu, Hannan; Westenfeld, Ralf; Aubin, Hug; Tudorache, Igor; Lichtenberg, Artur; Akhyari, Payam.
Afiliação
  • Immohr MB; Department of Cardiac Surgery, Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany.
  • Boeken U; Department of Cardiac Surgery, Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany.
  • Smiris K; Department of Cardiac Surgery, Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany.
  • Erbel-Khurtsidze S; Department of Cardiac Surgery, Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany.
  • Oehler D; Department of Cardiology, Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany.
  • Dalyanoglu H; Department of Cardiac Surgery, Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany.
  • Westenfeld R; Department of Cardiology, Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany.
  • Aubin H; Department of Cardiac Surgery, Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany.
  • Tudorache I; Department of Cardiac Surgery, Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany.
  • Lichtenberg A; Department of Cardiac Surgery, Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany.
  • Akhyari P; Department of Cardiac Surgery, Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany.
Thorac Cardiovasc Surg ; 70(6): 467-474, 2022 09.
Article em En | MEDLINE | ID: mdl-34894633
BACKGROUND: During heart transplantation (HTx), tip of the leads of cardiac implantable electrophysiological devices (CIEPD) has to be cut when resecting the heart. Timing of the removal of the remaining device and leads is still discussed controversially. METHODS: Between 2010 and 2021, n = 201 patients underwent HTx, of those n = 124 (61.7%) carried a present CIEPD. These patients were divided on the basis of the time of complete device removal (combined procedure with HTx, n = 40 or staged procedure, n = 84). RESULTS: CIEPD was removed 11.4 ± 6.7 days after the initial HTx in staged patients. Dwelling time, number of leads as well as incidence of retained components (combined: 8.1%, staged: 7.7%, p = 1.00) were comparable between both groups. While postoperative incidence of infections (p = 0.52), neurological events (p = 0.47), and acute kidney injury (p = 0.44) did not differ, staged patients suffered more often from primary graft dysfunction with temporary mechanical assistance (combined: 20.0%, staged: 40.5%, p = 0.03). Consecutively, stay on intensive care unit (p = 0.02) was prolonged and transfusions of red blood cells (p = 0.15) and plasma (p = 0.06) as well as re-thoracotomy for thoracic bleeding complications (p = 0.10) were numerically increased in this group. However, we did not observe any differences in postoperative survival. CONCLUSION: Presence of CIEPD is common in HTx patients. However, the extraction strategy of CIEPD most likely did not affect postoperative morbidity and mortality except primary graft dysfunction. Especially, retained components, blood transfusions, and infective complications are not correlated to the timing of CIEPD removal.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coração Auxiliar / Transplante de Coração / Disfunção Primária do Enxerto / Insuficiência Cardíaca Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Thorac Cardiovasc Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Coração Auxiliar / Transplante de Coração / Disfunção Primária do Enxerto / Insuficiência Cardíaca Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Thorac Cardiovasc Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha