Your browser doesn't support javascript.
loading
Building a precise machine-specific time structure of the spot and energy delivery model for a cyclotron-based proton therapy system.
Zhao, Lewei; Liu, Gang; Zheng, Weili; Shen, Jiajian; Lee, Andrew; Yan, Di; Deraniyagala, Rohan; Stevens, Craig; Li, Xiaoqiang; Tang, Shikui; Ding, Xuanfeng.
Afiliação
  • Zhao L; Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI 48073, United States of America.
  • Liu G; Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI 48073, United States of America.
  • Zheng W; Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People's Republic of China.
  • Shen J; Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI 48073, United States of America.
  • Lee A; Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ 85054, United States of America.
  • Yan D; Texas center for Proton Therapy, Irving, TX 75063, United States of America.
  • Deraniyagala R; Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI 48073, United States of America.
  • Stevens C; Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI 48073, United States of America.
  • Li X; Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI 48073, United States of America.
  • Tang S; Department of Radiation Oncology, Beaumont Health System, Royal Oak, MI 48073, United States of America.
  • Ding X; Texas center for Proton Therapy, Irving, TX 75063, United States of America.
Phys Med Biol ; 67(1)2022 01 17.
Article em En | MEDLINE | ID: mdl-34905732
ABSTRACT
Objective. We proposed an experimental approach to build a precise machine-specific beam delivery time (BDT) prediction and delivery sequence model for standard, volumetric, and layer repainting delivery based on a cyclotron accelerator system.Approach. Test fields and clinical treatment plans' log files were used to experimentally derive three main beam delivery parameters that impacted BDT energy layer switching time (ELST), spot switching time, and spot drill time. This derived machine-specific model includes standard, volumetric, and layer repainting delivery sequences. A total of 103 clinical treatment fields were used to validate the model.Main results. The study found that ELST is not stochastic in this specific machine. Instead, it is actually the data transmission time or energy selection time, whichever takes longer. The validation showed that the accuracy of each component of the BDT matches well between machine log files and the model's prediction. The average total BDT was about (-0.74 ± 3.33)% difference compared to the actual treatment log files, which is improved from the current commercial proton therapy system's prediction (67.22%±26.19%).Significance. An accurate BDT prediction and delivery sequence model was established for an cyclotron-based proton therapy system IBA ProteusPLUS®. Most institutions could adopt this method to build a machine-specific model for their own proton system.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia com Prótons Tipo de estudo: Prognostic_studies Idioma: En Revista: Phys Med Biol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia com Prótons Tipo de estudo: Prognostic_studies Idioma: En Revista: Phys Med Biol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos