Your browser doesn't support javascript.
loading
Is Porcine Small Intestinal Submucosal Extracellular Matrix (ECM) a Suitable Material for Right Ventricular Outflow Tract Reconstruction in Association With Pulmonary Valve Replacement?
Burke, Christopher R; Lewis, Erik; Schreiter, Nicholas A; Bartlett, Heather; Krieger, Eric V; Anagnostopoulos, Petros V; Verrier, Edward D; Hermsen, Joshua L.
Afiliação
  • Burke CR; 7284University of Washington, Seattle, WA, USA.
  • Lewis E; 7284University of Washington, Seattle, WA, USA.
  • Schreiter NA; 5228University of Wisconsin, Madison, WI, USA.
  • Bartlett H; 5228University of Wisconsin, Madison, WI, USA.
  • Krieger EV; 7284University of Washington, Seattle, WA, USA.
  • Anagnostopoulos PV; 5228University of Wisconsin, Madison, WI, USA.
  • Verrier ED; 7284University of Washington, Seattle, WA, USA.
  • Hermsen JL; 5228University of Wisconsin, Madison, WI, USA.
World J Pediatr Congenit Heart Surg ; 13(4): 518-521, 2022 07.
Article em En | MEDLINE | ID: mdl-34985359
ABSTRACT
Pulmonary valve replacement (PVR) with right ventricular outflow tract (RVOT) reconstruction is a common congenital cardiac operation. Porcine submucosal intestinal-derived extracellular matrix (ECM) patches have been used for RVOT reconstruction. We present 2 adult patients with Tetralogy of Fallot who underwent PVR with RVOT reconstruction utilizing ECM. Both cases required reoperation due to patch dehiscence causing a large paravalvular leak. One patient also had a pseudoaneurysm associated with ECM dehiscence. There may be a propensity for ECM dehiscence in this application and, based on these cases, we recommend avoidance of ECM in RVOT reconstruction with PVR. PVR patients repaired with ECM should be monitored for this complication.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Pulmonar / Insuficiência da Valva Pulmonar / Tetralogia de Fallot / Implante de Prótese de Valva Cardíaca / Procedimentos Cirúrgicos Cardíacos Tipo de estudo: Risk_factors_studies Limite: Animals / Humans Idioma: En Revista: World J Pediatr Congenit Heart Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Pulmonar / Insuficiência da Valva Pulmonar / Tetralogia de Fallot / Implante de Prótese de Valva Cardíaca / Procedimentos Cirúrgicos Cardíacos Tipo de estudo: Risk_factors_studies Limite: Animals / Humans Idioma: En Revista: World J Pediatr Congenit Heart Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos