Your browser doesn't support javascript.
loading
COVID-19 Serology Control Panel Using the Dried-Tube Specimen Method.
Windsor, William J; Knight, Vijaya; Merkel, Patricia A; Lamb, Molly M; Tucker, Heidi R; Carson, Kyle; Howard, Kelly M; Yates, Jennifer L; Santiago, Mario L; McCarthy, Mary K; Morrison, Thomas E; Kedl, Ross M; Frazer-Abel, Ashley; Guo, Kejun; Andersen, Gillian; Huey, Leah; Barrett, Bradley S; Colón-Franco, Jessica M; Lee, William T; Chu, May C.
Afiliação
  • Windsor WJ; Colorado School of Public Health, Anschutz Medical Campus, Aurora, Colorado.
  • Knight V; Children's Hospital Colorado, Anschutz Medical Campus, Aurora, Colorado.
  • Merkel PA; Children's Hospital Colorado, Anschutz Medical Campus, Aurora, Colorado.
  • Lamb MM; Colorado School of Public Health, Anschutz Medical Campus, Aurora, Colorado.
  • Tucker HR; Division of Infectious Diseases, Wadsworth Center, New York State Department of Health, Albany, New York.
  • Carson K; Division of Infectious Diseases, Wadsworth Center, New York State Department of Health, Albany, New York.
  • Howard KM; Division of Infectious Diseases, Wadsworth Center, New York State Department of Health, Albany, New York.
  • Yates JL; Division of Infectious Diseases, Wadsworth Center, New York State Department of Health, Albany, New York.
  • Santiago ML; The School of Public Health, The University at Albany, Albany, New York.
  • McCarthy MK; University of Colorado Anschutz Medical Campus, Aurora, Colorado.
  • Morrison TE; University of Colorado Anschutz Medical Campus, Aurora, Colorado.
  • Kedl RM; University of Colorado Anschutz Medical Campus, Aurora, Colorado.
  • Frazer-Abel A; University of Colorado Anschutz Medical Campus, Aurora, Colorado.
  • Guo K; University of Colorado Anschutz Medical Campus, Aurora, Colorado.
  • Andersen G; University of Colorado Anschutz Medical Campus, Aurora, Colorado.
  • Huey L; University of Colorado Anschutz Medical Campus, Aurora, Colorado.
  • Barrett BS; Children's Hospital Colorado, Anschutz Medical Campus, Aurora, Colorado.
  • Colón-Franco JM; University of Colorado Anschutz Medical Campus, Aurora, Colorado.
  • Lee WT; Cleveland Clinic, Cleveland, Ohio.
  • Chu MC; Division of Infectious Diseases, Wadsworth Center, New York State Department of Health, Albany, New York.
Am J Trop Med Hyg ; 106(2): 562-565, 2022 01 07.
Article em En | MEDLINE | ID: mdl-34996045
ABSTRACT
The dried-tube specimen (DTS) procedure was used to develop the COVID-19 serology control panel (CSCP). The DTS offers the benefit of shipping materials without a cold chain, allowing for greater access without deterioration of material integrity. Samples in the panel were sourced from COVID-19 convalescent persons from March to May 2020. The immunoglobulin subtypes (total Ig, IgM, and IgG) and their respective reactivity to severe acute respiratory syndrome coronavirus 2 nucleocapsid, spike, and receptor-binding domain antigens of the samples were delineated and compared with the WHO International Standard to elucidate the exact binding antibody units of each CSCP sample and ensure the CSCP provides adequate reactivity for different types of serological test platforms. We distribute the CSCP as a kit with five coded tubes to laboratories around the world to be used to compare test kits for external quality assurance, for harmonizing laboratory testing, and for use as training materials for laboratory workers.