Your browser doesn't support javascript.
loading
Technical features, perioperative and anatomical outcomes of a standardized suturing pattern for robotic sacrocolpopexy.
Giannini, Andrea; Russo, Eleonora; Misasi, Giulia; Falcone, Maria; Caretto, Marta; Morganti, Riccardo; Mannella, Paolo; Simoncini, Tommaso.
Afiliação
  • Giannini A; Department of Clinical and Experimental Medicine, Division of Obstetrics and Gynecology, University of Pisa, Via Roma, 67, 56126, Pisa, Italy. andrea.giannini@unipi.it.
  • Russo E; Department of Clinical and Experimental Medicine, Division of Obstetrics and Gynecology, University of Pisa, Via Roma, 67, 56126, Pisa, Italy.
  • Misasi G; Department of Clinical and Experimental Medicine, Division of Obstetrics and Gynecology, University of Pisa, Via Roma, 67, 56126, Pisa, Italy.
  • Falcone M; Department of Clinical and Experimental Medicine, Division of Obstetrics and Gynecology, University of Pisa, Via Roma, 67, 56126, Pisa, Italy.
  • Caretto M; Department of Clinical and Experimental Medicine, Division of Obstetrics and Gynecology, University of Pisa, Via Roma, 67, 56126, Pisa, Italy.
  • Morganti R; Department of Clinical and Experimental Medicine, Division of Obstetrics and Gynecology, University of Pisa, Via Roma, 67, 56126, Pisa, Italy.
  • Mannella P; Department of Clinical and Experimental Medicine, Division of Obstetrics and Gynecology, University of Pisa, Via Roma, 67, 56126, Pisa, Italy.
  • Simoncini T; Department of Clinical and Experimental Medicine, Division of Obstetrics and Gynecology, University of Pisa, Via Roma, 67, 56126, Pisa, Italy.
Int Urogynecol J ; 33(11): 3085-3092, 2022 11.
Article em En | MEDLINE | ID: mdl-35037972
ABSTRACT
INTRODUCTION AND

HYPOTHESIS:

Several technical alternatives to repair mesh using laparoscopic sacrocolpopexy exist. We aim to describe the outcomes and surgical technique of robotic-assisted colpo-/cervicosacropexy using a standardized suturing scheme to repair the mesh.

METHODS:

We retrospectively reported data of 60 consecutive cases of robotic-assisted colpo-/cervicosacropexy for advanced multicompartmental prolapse using a standardized suturing design. We placed three non-absorbable stitches on the cervix or three absorbable stitches on the apex of the vaginal vault, six long-term absorbable stitches on the anterior vaginal wall deep to the basis of the vesical trigone, six similar posterior stitches with the deeper row of sutures down to the levator ani plane and three non-absorbable stitches on the sacral promontory as the cranial support for Y-shaped polypropylene mesh.

RESULTS:

Median operative time was 188 ± 43 min. All the procedures were successfully performed using a Da Vinci Si platform in a three-arm configuration, and no conversion to open or traditional laparoscopic surgery was needed. The length of hospital stay was 1.2 ± 1.7 days, and no readmission within 30 postoperative days was reported. At a follow-up of 12 and 24 months, no case of extrusion or exposure of the mesh occurred, and the retreatment rate was 6.7%.

CONCLUSIONS:

Our suturing technique is safe and effective, with negligible risk of complications and good medium-term results. It is plausible that robotic systems may facilitate precise, accurate and reproducible placement of the stitches, thereby favoring wider diffusion of minimally invasive treatment of advanced prolapse.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Laparoscopia / Prolapso de Órgão Pélvico / Procedimentos Cirúrgicos Robóticos Tipo de estudo: Observational_studies Limite: Female / Humans Idioma: En Revista: Int Urogynecol J Assunto da revista: GINECOLOGIA / UROLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Laparoscopia / Prolapso de Órgão Pélvico / Procedimentos Cirúrgicos Robóticos Tipo de estudo: Observational_studies Limite: Female / Humans Idioma: En Revista: Int Urogynecol J Assunto da revista: GINECOLOGIA / UROLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Itália