Diagnostic performance improvement with combined use of proteomics biomarker assay and breast ultrasound.
Ha, Su Min; Kim, Hong-Kyu; Kim, Yumi; Noh, Dong-Young; Han, Wonshik; Chang, Jung Min.
Afiliação
  • Ha SM; Department of Radiology, Seoul National University College of Medicine and Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 110-744, Republic of Korea.
  • Kim HK; Department of Surgery, Seoul National University College of Medicine and Seoul National University Hospital, Seoul, Republic of Korea.
  • Kim Y; Department of Surgery, Seoul National University College of Medicine and Seoul National University Hospital, Seoul, Republic of Korea.
  • Noh DY; Department of Surgery, CHA University Gangnam Medical Center, Seoul, Republic of Korea.
  • Han W; Department of Surgery, Seoul National University College of Medicine and Seoul National University Hospital, Seoul, Republic of Korea.
  • Chang JM; Department of Surgery, CHA University Gangnam Medical Center, Seoul, Republic of Korea.
Breast Cancer Res Treat ; 192(3): 541-552, 2022 Apr.
Article em En | MEDLINE | ID: mdl-35084623
PURPOSE: To investigate the combined use of blood-based 3-protein signature and breast ultrasound (US) for validating US-detected lesions. METHODS: From July 2011 to April 2020, women who underwent whole-breast US within at least 6 months from sampling period were retrospectively included. Blood-based 3-protein signature (Mastocheck®) value and US findings were evaluated. Following outcome measures were compared between US alone and the combination of Mastocheck® value with US: sensitivity, specificity, positive predictive value (PPV), negative predictive value, area under the receiver operating characteristic curve (AUC), and biopsy rate. RESULTS: Among the 237 women included, 59 (24.9%) were healthy individuals and 178 (75.1%) cancer patients. Mean size of cancers was 1.2 ± 0.8 cm. Median value of Mastocheck® was significantly different between nonmalignant (- 0.24, interquartile range [IQR] - 0.48, - 0.03) and malignant lesions (0.55, IQR - 0.03, 1.42) (P < .001). Utilizing Mastocheck® value with US increased the AUC from 0.67 (95% confidence interval [CI] 0.61, 0.73) to 0.81 (95% CI 0.75, 0.88; P < .001), and specificity from 35.6 (95% CI 23.4, 47.8) to 64.4% (95% CI 52.2, 76.6; P < .001) without loss in sensitivity. PPV was increased from 82.2 (95% CI 77.1, 87.3) to 89.3% (95% CI 85.0, 93.6; P < .001), and biopsy rate was significantly decreased from 79.3 (188/237) to 72.1% (171/237) (P < .001). Consistent improvements in specificity, PPV, and AUC were observed in asymptomatic women, in women with dense breast, and in those with normal/benign mammographic findings. CONCLUSION: Mastocheck® is an effective tool that can be used with US to improve diagnostic specificity and reduce false-positive findings and unnecessary biopsies.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Proteômica Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Female / Humans Idioma: En Revista: Breast Cancer Res Treat Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Proteômica Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Female / Humans Idioma: En Revista: Breast Cancer Res Treat Ano de publicação: 2022 Tipo de documento: Article