Your browser doesn't support javascript.
loading
Merits of multicolor imaging for tractional retinal detachment.
Gadde, Santosh Gopi Krishna; Sridharan, Akhila; Gurram, Nikitha Reddy; Poornachandra, B; Govindasamy, Nivedhitha; Jayadev, Chaitra.
Afiliação
  • Gadde SGK; Vitreoretina Services, Narayana Nethralaya, Bangalore, Karnataka, India.
  • Sridharan A; Vitreoretina Services, Narayana Nethralaya, Bangalore, Karnataka, India.
  • Gurram NR; Vitreoretina Services, Narayana Nethralaya, Bangalore, Karnataka, India.
  • Poornachandra B; Vitreoretina Services, Narayana Nethralaya, Bangalore, Karnataka, India.
  • Govindasamy N; Vitreoretina Services, Narayana Nethralaya, Bangalore, Karnataka, India.
  • Jayadev C; Vitreoretina Services, Narayana Nethralaya, Bangalore, Karnataka, India.
Indian J Ophthalmol ; 70(2): 465-470, 2022 Feb.
Article em En | MEDLINE | ID: mdl-35086217
ABSTRACT

PURPOSE:

To compare multicolor imaging (MCI) with Optos color fundus photography (OCFP) for the evaluation of morphology and extent of preretinal membranes in diabetic tractional retinal detachments (TRD).

METHODS:

In this retrospective study, 30 eyes with diabetic TRDs were imaged using the MCI feature of the Heidelberg Spectralis Spectral-domain optical coherence tomography (SD-OCT) and color photo using the Optos Daytona ultra-widefield fundus camera. Two investigators independently graded and determined the agreeability between the two modalities with respect to the extent of the TRD and preretinal membranes on the SD-OCT B-scan images.

RESULTS:

The MCI provided better visualization of the attachments and traction points of the posterior hyaloid face and preretinal membranes and is comparable to the SD-OCT B-scan images. The inter-rater agreeability rates for OCFP had a Kappa (κ) value of 0.37, while the MCI had a κ value of 0.46. When comparing between images of different wavelengths, grading using infrared reflectance (IR) had a poor agreement (-0.04 ± 0.04) while green reflectance (GR) (0.46 ± 0.32) and blue reflectance (BR) (0.53 ± 0.19) had a moderate agreement. The composite MCI and GR images also had comparatively higher intraclass coefficient when compared to the OCFP (0.25 [-0.09-0.55]) and IR (-0.03 [-0.39-0.34]) images.

CONCLUSION:

MCI is more sensitive for determining the extent of TRDs and for the detection of secondary membranes when compared to OCFP, thus, aiding in better surgical planning.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Descolamento Retiniano Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Revista: Indian J Ophthalmol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Descolamento Retiniano Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Revista: Indian J Ophthalmol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Índia