Your browser doesn't support javascript.
loading
Patient-specific instrumentation reduces deviations between planned and postosteotomy humeral retrotorsion and height in shoulder arthroplasty.
Rojas, J Tomás; Jost, Bernhard; Hertel, Ralph; Zipeto, Claudio; Van Rooij, Floris; Zumstein, Matthias A.
Afiliação
  • Rojas JT; Shoulder, Elbow and Orthopaedic Sports Medicine, Sonnenhof Orthopaedics, Bern, Switzerland; Department of Orthopaedics and Trauma Surgery, Hospital San José-Clínica Santa María, Santiago, Chile.
  • Jost B; Department of Orthopaedics and Traumatology, Kantonsspital, St.Gallen, Switzerland.
  • Hertel R; Department of Orthopaedics and Trauma Surgery, Lindenhofspital, Bern, Switzerland.
  • Zipeto C; Shoulder R & D Department, Medacta International SA, Castel San Pietro, Switzerland.
  • Van Rooij F; ReSurg SA, Nyon, Switzerland.
  • Zumstein MA; Shoulder, Elbow and Orthopaedic Sports Medicine, Sonnenhof Orthopaedics, Bern, Switzerland; Shoulder, Elbow Unit, Sportsclinicnumber1, Bern, Switzerland; Shoulder, Elbow and Orthopaedic Sports Medicine, Department of Orthopaedic Surgery and Traumatology, Inselspital, Bern University Hospital, Bern,
J Shoulder Elbow Surg ; 31(9): 1929-1937, 2022 Sep.
Article em En | MEDLINE | ID: mdl-35346846
ABSTRACT

BACKGROUND:

Patient-specific instrumentation (PSI) may potentially improve humeral osteotomy in shoulder arthroplasty. The purpose of this study was to compare the deviation between planned and postosteotomy humeral inclination, retrotorsion, and height in shoulder arthroplasty, using PSI vs. standard cutting guides (SCG).

METHODS:

Twenty fresh-frozen cadaveric specimens were allocated to undergo humeral osteotomy using either PSI or SCG, such that the 2 groups have similar age, gender, and side. Preosteotomy computed tomography (CT) scan was performed and used for the 3-dimensional (3D) planning. The osteotomy procedure was performed using a PSI designed for each specimen or an SCG depending on the group. A postosteotomy CT scan was performed. The preosteotomy and postosteotomy 3D CT scan reconstructions were superimposed to calculate the deviation between planned and postosteotomy inclination, retrotorsion, and height. Outliers were defined as cases with 1 or more of the following deviations >5° inclination, >10° retrotorsion, and >3 mm height. The deviation and outliers in inclination, retrotorsion, and height were compared between the 2 groups.

RESULTS:

The deviations between planned and postosteotomy parameters were similar among the PSI and SCG groups for inclination (P = .260), whereas they were significantly greater in the SCG group for retrotorsion (P < .001) and height (P = .003). There were 8 outliers in the SCG group, compared with only 1 outlier in the PSI group (P = .005). Most outliers in the SCG group were due to deviation >10° in retrotorsion.

CONCLUSION:

After 3D planning, PSI had less deviation between planned and postosteotomy humeral retrotorsion and height, relative to SCG.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Articulação do Ombro / Artroplastia do Ombro / Úmero Limite: Humans Idioma: En Revista: J Shoulder Elbow Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Chile

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Articulação do Ombro / Artroplastia do Ombro / Úmero Limite: Humans Idioma: En Revista: J Shoulder Elbow Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Chile