Your browser doesn't support javascript.
loading
Subacromial space measured by ultrasound imaging in asymptomatic subjects and patients with subacromial shoulder pain: an inter-rater reliability study.
Cavaggion, Claudia; Navarro-Ledesma, Santiago; Luque-Suarez, Alejandro; Juul-Kristensen, Birgit; Voogt, Lennard; Struyf, Filip.
Afiliação
  • Cavaggion C; Research Group MOVANT, Department of Rehabilitation Sciences and Physiotherapy (REVAKI), Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium.
  • Navarro-Ledesma S; Department of Physiotherapy, Faculty of Health Sciences, Campus of Melilla, University of Granada, Melilla, Spain.
  • Luque-Suarez A; Department of Physiotherapy, University of Malaga, Malaga, Spain.
  • Juul-Kristensen B; Instituto de Investigacion Biomedica de Malaga (IBIMA), Malaga, Spain.
  • Voogt L; Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark.
  • Struyf F; Department of Physical Therapy Studies and Research Centre for Health Care Innovations, Rotterdam University of Applied Sciences, Rotterdam, Netherlands.
Physiother Theory Pract ; 39(10): 2196-2207, 2023 Oct 03.
Article em En | MEDLINE | ID: mdl-35505639
BACKGROUND: Acromiohumeral distance (AHD) and supraspinatus tendon thickness (STT) measured by ultrasound (US) can be combined in the occupation ratio (OR). Inter-rater reliability on these subacromial measures depends on the US experience of raters and on the subject status, differing between asymptomatic or patients with subacromial shoulder pain (SSP). OBJECTIVE: To evaluate inter-rater reliability between two raters with different US experience (experienced examiner and novice examiner). METHODS: In total, 20 asymptomatic subjects (controls) and 21 patients with SSP were examined on one shoulder. Inter-rater reliability was evaluated with intraclass correlation coefficient (ICC). RESULTS: ICC for controls was good for AHD at rest and at 60° (0.76-0.77), moderate for STT and AHD at 60° with weights (0.53-0.72), while OR was poorly reliable (below 0.44). ICC for SSP was moderate for AHD at rest and at 60°, STT, OR at rest and at 60° (0.52-0.74) and poor for AHD at 60° with weights and OR at 60° with weights (0.33-0.36). Bland-Altman plots showed systematic bias. CONCLUSION: Inter-rater reliability varied largely from poor to good between two examiners with different US experience. Clinicians might use the US as additional tool for detecting the subacromial structures, but a structured training including also symptomatic subjects is suggested. Researchers may further investigate the OR in matched case-control studies, and an overall agreement phase is recommended before starting the inter-rater reliability phase.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ombro / Dor de Ombro Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Physiother Theory Pract Assunto da revista: MEDICINA FISICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ombro / Dor de Ombro Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Physiother Theory Pract Assunto da revista: MEDICINA FISICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Bélgica