Your browser doesn't support javascript.
loading
Ultra high-resolution biomechanics suggest that substructures within insect mechanosensors decisively affect their sensitivity.
Dinges, Gesa F; Bockemühl, Till; Iacoviello, Francesco; Shearing, Paul R; Büschges, Ansgar; Blanke, Alexander.
Afiliação
  • Dinges GF; Institute of Zoology, University of Cologne, 50674 Cologne, Germany.
  • Bockemühl T; Institute of Zoology, University of Cologne, 50674 Cologne, Germany.
  • Iacoviello F; Electrochemical Innovation Lab, Department of Chemical Engineering, University College London, WC1DE 6BT London, UK.
  • Shearing PR; Electrochemical Innovation Lab, Department of Chemical Engineering, University College London, WC1DE 6BT London, UK.
  • Büschges A; Institute of Zoology, University of Cologne, 50674 Cologne, Germany.
  • Blanke A; Institute of Zoology, University of Cologne, 50674 Cologne, Germany.
J R Soc Interface ; 19(190): 20220102, 2022 05.
Article em En | MEDLINE | ID: mdl-35506211
Insect load sensors, called campaniform sensilla (CS), measure strain changes within the cuticle of appendages. This mechanotransduction provides the neuromuscular system with feedback for posture and locomotion. Owing to their diverse morphology and arrangement, CS can encode different strain directions. We used nano-computed tomography and finite-element analysis to investigate how different CS morphologies within one location-the femoral CS field of the leg in the fruit fly Drosophila-interact under load. By investigating the influence of CS substructures' material properties during simulated limb displacement with naturalistic forces, we could show that CS substructures (i.e. socket and collar) influence strain distribution throughout the whole CS field. Altered socket and collar elastic moduli resulted in 5% relative differences in displacement, and the artificial removal of all sockets caused differences greater than 20% in cap displacement. Apparently, CS sockets support the distribution of distal strain to more proximal CS, while collars alter CS displacement more locally. Harder sockets can increase or decrease CS displacement depending on sensor location. Furthermore, high-resolution imaging revealed that sockets are interconnected in subcuticular rows. In summary, the sensitivity of individual CS is dependent on the configuration of other CS and their substructures.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mecanotransdução Celular / Insetos Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J R Soc Interface Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mecanotransdução Celular / Insetos Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J R Soc Interface Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha