Your browser doesn't support javascript.
loading
Fabrication of an (α-Mn2O3:Co)-decorated CNT highly sensitive screen printed electrode for the optimization and electrochemical determination of cyclobenzaprine hydrochloride using response surface methodology.
Abdel-Raoof, Ahmed M; Osman, Ayman O E; El-Desouky, Ebrahim A; Abdel-Fattah, Ashraf; Abdul-Kareem, Rady F; Elgazzar, Elsayed.
Afiliação
  • Abdel-Raoof AM; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy (Boys), Al-Azhar University 11751, Nasr City Cairo Egypt Ahmedmeetyazeed79@Azhar.edu.eg Ahmedmeetyazeed79@yahoo.com.
  • Osman AOE; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy (Boys), Al-Azhar University 11751, Nasr City Cairo Egypt Ahmedmeetyazeed79@Azhar.edu.eg Ahmedmeetyazeed79@yahoo.com.
  • El-Desouky EA; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy (Boys), Al-Azhar University 11751, Nasr City Cairo Egypt Ahmedmeetyazeed79@Azhar.edu.eg Ahmedmeetyazeed79@yahoo.com.
  • Abdel-Fattah A; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy (Boys), Al-Azhar University 11751, Nasr City Cairo Egypt Ahmedmeetyazeed79@Azhar.edu.eg Ahmedmeetyazeed79@yahoo.com.
  • Abdul-Kareem RF; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy (Boys), Al-Azhar University 11751, Nasr City Cairo Egypt Ahmedmeetyazeed79@Azhar.edu.eg Ahmedmeetyazeed79@yahoo.com.
  • Elgazzar E; Department of Physics, Faculty of Science, Suez Canal University Ismailia Egypt.
RSC Adv ; 10(42): 24985-24993, 2020 Jun 29.
Article em En | MEDLINE | ID: mdl-35517446
ABSTRACT
A new chemically optimized screen-printed electrode modified with a cobalt-doped α-Mn2O3 nanostructure on carbon nanotube paste (α-Mn2O3Co@CNTs) has been constructed for the recognition of cyclobenzaprine hydrochloride. The prepared paste is based on the incorporation of oxide ion conductors, such as the α-Mn2O3 nanostructure with cobalt and ion pairs (tetraphenyl borate coupled with the drug), as electroactive species in the screen-printed electrode to increase the sensor surface area and decrease electrical resistance. The central composite design is a useful methodology for the estimation and modeling of the exact optimum parameters specifically designed for this process. This is a good way to graphically clarify the relationship between various experimental variables and the slope response. The proposed sensor, α-Mn2O3Co@CNTs, possesses very good sensitivity and the ability to recognize the drug over the concentration range of 1 × 10-6 to 1 × 10-2 mol L-1 at 25 ± °C with a detection limit of 2.84 × 10-7 mol L-1. It exhibits a reproducible potential and stable linear response for six months at a Nernstian slope of 58.96 ± 0.76 mV per decade. The proposed electrode approach has been successfully applied in the direct determination of the drug in its pure and dosage forms.

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: RSC Adv Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: RSC Adv Ano de publicação: 2020 Tipo de documento: Article