ABSTRACT

BACKGROUND:

Radiographic lucency around a smooth pelvic rod (Galveston/unit rod technique) or sacroiliac/iliac screw following spinal fusion in children with nonambulatory spastic cerebral palsy (CP) has been described as a "windshield wiper" phenomenon. We evaluated demographics, radiographs, and complications in 101 cases from a single center to determine prevalence, risk factors, and complications associated with persistent radiographic lucency from 1 to 5 years following spinal fusion.

METHODS:

Inclusion criteria were diagnosis of nonambulatory spastic quadriplegic CP [Gross Motor Function Classification System (GMFCS) IV-V], under 18 years of age, scoliosis treated by posterior fusion from upper thoracic to sacrum with pelvic fixation (Galveston rod, iliac screw, or sacroiliac screw), adequate radiographs (preoperative, immediate postoperative, first-year, and second-year), and minimum 5-year follow-up. We evaluated demographics, radiographic parameters, comorbidities, scoliosis curve type, type of pelvic screw/rod, use of off-set connector, screw width, associated with posterior column osteotomy and/or additional anterior spinal release concurrent with posterior spine fusion, and infection over the follow-up period. Specific attention was given to the area and shape of the radiographic lucency. The logistic regression analysis was performed for continuous and categorical variables to define risk factors ( P =0.05).

RESULTS:

In 101 patients, data were collected at mean intervals of 1-year, 2-year, and >5-year follow-up and were 12.9±1.5, 25.8±2.5, and 81.5±23.0 months, respectively. Prevalence of pelvic rod/screw radiographic lucency was unchanged at 33%, 35%, and 24% at 1-year, 2-year, and >5-year follow-up, respectively, and radiographic parameters did not change ( P >0.05). Furthermore, no risk factors or complications were associated with radiographic lucency around pelvic rods/screws ( P >0.05).

CONCLUSION:

In patients with spastic nonambulatory CP who had scoliosis treated with posterior spinal fusion from upper thorax to pelvis, the prevalence of pelvic rod/screw lucency is high. Persistent lucency >2 mm around pelvic implants is not clinically significant, does not warrant advanced imaging, or indicate a complication if stable over time and wider distally than proximally. LEVEL OF EVIDENCE Level III.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Escoliose / Fusão Vertebral / Paralisia Cerebral Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Child / Humans Idioma: En Revista: J Pediatr Orthop Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Escoliose / Fusão Vertebral / Paralisia Cerebral Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Child / Humans Idioma: En Revista: J Pediatr Orthop Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha