Your browser doesn't support javascript.
loading
The accuracy of virtual surgical planning in segmental Le Fort I surgery: A comparison of planned and actual outcome.
Chu, Yuxian; Ye, Bin; Wu, Qionghui; Wang, Yu; Wang, Peng; Li, Jihua.
Afiliação
  • Chu Y; State Key Laboratory of Oral Diseases and Department of Oral and Maxillofacial Surgery, West China College of Stomatology, Sichuan University, Chengdu, China.
  • Ye B; State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Orthognathic & TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Cheng du, China.
  • Wu Q; State Key Laboratory of Oral Diseases and Department of Oral and Maxillofacial Surgery, West China College of Stomatology, Sichuan University, Chengdu, China.
  • Wang Y; State Key Laboratory of Oral Diseases and Department of Oral and Maxillofacial Surgery, West China College of Stomatology, Sichuan University, Chengdu, China.
  • Wang P; State Key Laboratory of Oral Diseases and Department of Oral and Maxillofacial Surgery, West China College of Stomatology, Sichuan University, Chengdu, China.
  • Li J; State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Orthognathic & TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Cheng du, China. Electronic address: leejimwa6698@sohu.com.
J Plast Reconstr Aesthet Surg ; 75(8): 2719-2726, 2022 08.
Article em En | MEDLINE | ID: mdl-35667995
Segmental Le Fort I surgery is an effective technique to correct complicated dentomaxillofacial deformities. This retrospective study evaluated the accuracy of segmental Le Fort I surgery under the guidance of virtual surgical planning (VSP). A total of 129 patients who accepted segmental Le Fort I surgery were investigated in this study. VSP was transferred to segmental surgery with different pieces precisely with the aid of 3D-printed surgical templates and splints. The surgical result was evaluated by postoperative complications, color distance maps, and quantitative accuracy analysis. Outcomes showed that the VSP was successfully transferred to actual surgery with high accuracy. The overall mean linear difference was 1.28 mm, and the overall mean angular difference was 2.4°. Except for one case of root injury, there was no serious complication recorded. The results suggested that VSP was a reliable assistance for segmental Le Fort I surgery.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cirurgia Assistida por Computador / Procedimentos Cirúrgicos Ortognáticos Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: J Plast Reconstr Aesthet Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cirurgia Assistida por Computador / Procedimentos Cirúrgicos Ortognáticos Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: J Plast Reconstr Aesthet Surg Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China