Your browser doesn't support javascript.
loading
Transvenous pacing approach for atrioventricular block in fontan - Possibility of transvenous approach by electrophysiological assessment.
Akazawa, Yusuke; Higaki, Takashi; Nagai, Takayuki; Sasaki, Yasuhiro; Asagi, Yasushi; Moritani, Tomozo; Inaba, Shinji; Nishiyama, Hikaru; Eguchi, Mariko; Yamaguchi, Osamu.
Afiliação
  • Akazawa Y; Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan.
  • Higaki T; Department of Regional Pediatrics and Perinatology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan.
  • Nagai T; Department of Pediatrics, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan.
  • Sasaki Y; Department of Regional Pediatrics and Perinatology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan.
  • Asagi Y; Department of Pediatrics, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan.
  • Moritani T; Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan.
  • Inaba S; Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan.
  • Nishiyama H; Department of Medical Engineering Center, Ehime University Hospital, Shitsukawa, Toon, Ehime, Japan.
  • Eguchi M; Department of Pediatrics, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan.
  • Yamaguchi O; Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, Japan.
J Cardiol Cases ; 25(6): 389-391, 2022 Jun.
Article em En | MEDLINE | ID: mdl-35685262
In extracardiac Fontan, an epicardial pacemaker implantation has many limitations, especially given that it is highly invasive and a high-risk procedure due to repeat thoracotomy. Herein we illustrate a case with the possibility of transvenous pacing in extracardiac Fontan being less invasive and lower risk transvenous dual-chamber pacemaker implantation by electrophysiological assessment. .
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: J Cardiol Cases Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: J Cardiol Cases Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão