Your browser doesn't support javascript.
loading
Hearing aid effectiveness on patients with chronic tinnitus and associated hearing loss.
Simonetti, Patricia; Vasconcelos, Laura Garcia; Gândara, Mara Rocha; Lezirovitz, Karina; Medeiros, Ítalo Roberto Torres de; Oiticica, Jeanne.
Afiliação
  • Simonetti P; Universidade de São Paulo, Faculdade de Medicina, Hospital das Clínicas (HCFMUSP), Departamento de Otorrinolaringologia, São Paulo, SP, Brazil. Electronic address: patriciasimonetti3@gmail.com.
  • Vasconcelos LG; Universidade de São Paulo, Faculdade de Medicina, Hospital das Clínicas (HCFMUSP), Departamento de Otorrinolaringologia, São Paulo, SP, Brazil.
  • Gândara MR; Universidade de São Paulo, Faculdade de Medicina, Hospital das Clínicas (HCFMUSP), Departamento de Otorrinolaringologia, São Paulo, SP, Brazil.
  • Lezirovitz K; Universidade de São Paulo, Faculdade de Medicina, Hospital das Clínicas (HCFMUSP), Departamento de Otorrinolaringologia, São Paulo, SP, Brazil.
  • Medeiros ÍRT; Universidade de São Paulo, Faculdade de Medicina, Hospital das Clínicas (HCFMUSP), Departamento de Otorrinolaringologia, São Paulo, SP, Brazil.
  • Oiticica J; Universidade de São Paulo, Faculdade de Medicina, Hospital das Clínicas (HCFMUSP), Departamento de Otorrinolaringologia, São Paulo, SP, Brazil.
Braz J Otorhinolaryngol ; 88 Suppl 3: S164-S170, 2022.
Article em En | MEDLINE | ID: mdl-35729042
ABSTRACT

OBJECTIVE:

Our study aimed to measure the effectiveness of using HA in reducing the disturbance caused by tinnitus.

METHODS:

Study was designed as a within-subjects clinical trial. Nineteen patients with chronic tinnitus and untreated sensorineural hearing loss were under counseling, HA fitting and 6 months follow-up. Tinnitus assessment was performed with Tinnitus Handicap Inventory (THI), Visual Analog Scale (VAS), pitch and loudness matching, and Minimum Masking Level measurements (MML).

RESULTS:

following 6 months of HA use, a reduction in reported tinnitus and hearing handicap scales scores was observed both statistically and clinically. The pitch and loudness matching, as well as MML at the baseline and final evaluation were compared. MML's thresholds reduced significantly after 6 months of HA use.

CONCLUSION:

Our study has provided evidence that HA fitting is a valuable treatment strategy for chronic tinnitus relief and associated hearing loss subtype of patient.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Zumbido / Surdez / Auxiliares de Audição / Perda Auditiva / Perda Auditiva Neurossensorial Tipo de estudo: Risk_factors_studies Limite: Humans Idioma: En Revista: Braz J Otorhinolaryngol Assunto da revista: OTORRINOLARINGOLOGIA Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Zumbido / Surdez / Auxiliares de Audição / Perda Auditiva / Perda Auditiva Neurossensorial Tipo de estudo: Risk_factors_studies Limite: Humans Idioma: En Revista: Braz J Otorhinolaryngol Assunto da revista: OTORRINOLARINGOLOGIA Ano de publicação: 2022 Tipo de documento: Article