Development of transient trapping micellar electrokinetic chromatography coupled with mass spectrometry for steroids analysis.
Manmana, Yanawut; Liu, Chenchen; Koino, Hiroshi; Sueyoshi, Kenji; Kitagawa, Fumihiko; Kubo, Takuya; Otsuka, Koji.
Afiliação
  • Manmana Y; Graduate School of Engineering, Kyoto University, Kyoto, Japan.
  • Liu C; Graduate School of Engineering, Kyoto University, Kyoto, Japan.
  • Koino H; Graduate School of Engineering, Kyoto University, Kyoto, Japan.
  • Sueyoshi K; Graduate School of Engineering, Osaka Prefecture University, Osaka, Japan.
  • Kitagawa F; Graduate School of Science and Technology, Hirosaki University, Aomori, Japan.
  • Kubo T; Graduate School of Engineering, Kyoto University, Kyoto, Japan.
  • Otsuka K; Graduate School of Engineering, Kyoto University, Kyoto, Japan.
Chirality ; 34(10): 1328-1337, 2022 10.
Article em En | MEDLINE | ID: mdl-35754139
An on-line sample preconcentration technique based on transient trapping (tr-trapping) in micellar electrokinetic chromatography (MEKC) was applied for steroid detection with UV (tr-trapping-UV) and electrospray ionization mass spectrometry detection (tr-trapping-ESI-MS). ESI-MS was used to improve the sensitivity in MEKC. The MEKC separation was carried out using volatile ammonium formate as a background solution to facilitate the coupling with ESI-MS. The partial introduction of a sodium dodecyl sulfate (SDS) micellar solution before the introduction of a sample solution to the capillary provided the effective preconcentration of analytes. At the same time, the SDS micelle would not enter the ESI-MS system, so its interference in ESI-MS detection was suppressed under the optimal condition, then five steroids can be separated by the developed method. In tr-trapping-ESI-MS, an acidic condition of pH 3.5 was employed to suppress the electroosmotic flow, which can avoid micellar solution migrating to the MS instrument. The developed method showed that the micellar solution requires a twofold slower time than the sample to migrate along the column, which can prohibit the cause of the problem with the MS instrument and interference signal of SDS in the steroid's detection. The tr-trapping-ESI-MS protocol showed up to 540-fold enhancements of the peak intensity and 50-fold improvement of the limit of detection compared with capillary zone electrophoresis using androsterone as a model sample.