Your browser doesn't support javascript.
loading
Determination of naphthenic acids in produced water by using microchip electrophoresis with integrated contactless conductivity detection.
Pinheiro, Kemilly M P; Duarte, Lucas M; Rodrigues, Marcella F; Vaz, Boniek G; Junior, Iris Medeiros; Carvalho, Rogerio M; Coltro, Wendell K T.
Afiliação
  • Pinheiro KMP; Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil.
  • Duarte LM; Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil; Instituto de Química, Universidade Federal Fluminense, Niterói, RJ 24020-141, Brazil.
  • Rodrigues MF; Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil.
  • Vaz BG; Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil.
  • Junior IM; Centro de Pesquisas e Desenvolvimento Leopoldo Américo Miguez de Mello (CENPES), Rio de Janeiro, RJ 21040-000, Brazil.
  • Carvalho RM; Centro de Pesquisas e Desenvolvimento Leopoldo Américo Miguez de Mello (CENPES), Rio de Janeiro, RJ 21040-000, Brazil.
  • Coltro WKT; Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, SP 13084-971, Brazil. Electronic address: wendell@ufg.br.
J Chromatogr A ; 1677: 463307, 2022 Aug 16.
Article em En | MEDLINE | ID: mdl-35834889
This study reports for the first time the use of a microchip electrophoresis (ME) device with integrated capacitively coupled contactless conductivity detection (C4D) to analyze naphthenic acids in produced water. A mixture containing 9-anthracenecarboxylic, 1-naphthoic, and benzoic acids was separated and detected using a running buffer composed of 10 mmol L-1 carbonate buffer (pH = 10.2). The separation was achieved within ca. 140 s with baseline resolution greater than 2 and efficiency values ranging from 1.9 × 105 to 2.4 × 105 plates m-1. The developed methodology provided linear correlation with determination coefficients greater than 0.992 for the concentration ranges between 50 and 250 µmol L-1 for benzoic and 9-anthracenecarboxylic acids, and between 50 and 200 µmol L-1 for 1-naphthoic acid. The achieved limit of detection values varied between 4.7 and 7.7 µmol L-1. The proposed methodology revealed satisfactory repeatability with RSD values for a sequence of eight injections between 5.5 and 7.7% for peak areas and lower than 1% for migration times. In addition, inter-day precision was evaluated for sixteen injections (a sequence of four injections performed during four days), and the RSD values were lower than 11.5 and 4.9% for peak areas and migration time, respectively. Five produced water samples were analyzed, and it was possible to detect and quantify 9-anthracenecarboxylic acid. The concentrations ranged from 1.05 to 2.24 mmol L-1 with recovery values between 90.8 and 96.0%. ME-C4D demonstrated satisfactory analytical performance for determining naphthenic acids in produced water for the first time, which is useful for petroleum or oil industry investigation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Eletroforese em Microchip Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Chromatogr A Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Eletroforese em Microchip Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Chromatogr A Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil