Your browser doesn't support javascript.
loading
The Accuracy of Commercially Available Fitness Trackers in Patients after Stroke.
Holubová, Anna; Malá, Eliska; Hoidekrová, Kristýna; Petioký, Jakub; Duris, Andrea; Muzík, Jan.
Afiliação
  • Holubová A; Faculty of Biomedical Engineering, Czech Technical University in Prague, 272 01 Kladno, Czech Republic.
  • Malá E; Faculty of Biomedical Engineering, Czech Technical University in Prague, 272 01 Kladno, Czech Republic.
  • Hoidekrová K; First Faculty of Medicine, Charles University and General University Hospital, 128 00 Prague, Czech Republic.
  • Petioký J; Rehabilitation Centre Kladruby, 257 62 Kladruby, Czech Republic.
  • Duris A; Rehabilitation Centre Kladruby, 257 62 Kladruby, Czech Republic.
  • Muzík J; Third Faculty of Medicine, Charles University in Prague, 100 00 Prague, Czech Republic.
Sensors (Basel) ; 22(19)2022 Sep 28.
Article em En | MEDLINE | ID: mdl-36236491
ABSTRACT

Background:

Fitness trackers could represent an easy-to-use and cheap tool for continuous tracking of physical activity of stroke survivors during the period of their recovery at home. The aim of the study was to examine the accuracy of the Fitbit activity tracker in locomotor activity monitoring of stroke survivors with respect to gait disorders, walking speed, walking aid, and placement of the tracker on body.

Methods:

Twenty-four ambulatory stroke survivors (15 men and 9 women) with locomotion/gait disorder were involved in the study. Patients underwent two walking tests with the Fitbit Alta HR trackers attached on 5 different places on body. The accuracy of the trackers has been analyzed on 3 groups of patients-those walking without any walking aid, those using a single-point stick and those using a rolling walker.

Results:

For no-aid patients, the most accurate place was the waist. Patients with a single-point stick revealed the smallest deviations for a tracker attached to a healthy lower limb, and patients with a rolling walker revealed the smallest deviations for a tracker attached on the paretic lower limb.

Conclusions:

An accuracy comparable with the healthy population can be reached for all of the three groups of patients, while fulfilling the conditions for minimum speed of 2 km/h and optimal placement of the trackers with respect to a walking aid and aspect to impairment.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Acidente Vascular Cerebral / Monitores de Aptidão Física Limite: Female / Humans / Male Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: República Tcheca

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Acidente Vascular Cerebral / Monitores de Aptidão Física Limite: Female / Humans / Male Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: República Tcheca