Your browser doesn't support javascript.
loading
An eco-friendly matrix-augmented fluorescence spectroscopic approach for the analysis of mitoxantrone, an oncogenic therapy; application to the dosage form and biological matrices.
Hamad, Ahmed A; Hassan, Yasser F; Eltoukhi, Walid E; Derayea, Sayed M; Abourehab, Mohammed A S; Mohammed, Bassam S.
Afiliação
  • Hamad AA; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University, Assiut Branch, Assiut, Egypt.
  • Hassan YF; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University, Assiut Branch, Assiut, Egypt.
  • Eltoukhi WE; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University, Assiut Branch, Assiut, Egypt.
  • Derayea SM; Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia, Egypt.
  • Abourehab MAS; Department of Pharmaceutics, College of Pharmacy, Umm Al-Qura University, Makkah, Saudi Arabia.
  • Mohammed BS; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Menoufia University, Shebin El-Kom, Egypt.
Luminescence ; 38(2): 166-175, 2023 Feb.
Article em En | MEDLINE | ID: mdl-36609821
ABSTRACT
Mitoxantrone (MXN) is a synthetic anthracenedione oncogenic therapy. It is often prescribed as an anticancer agent to manage a variety of cancers. A green, fast, and easy fluorimetric technique for the assay of MXN as a topoisomerase type II enzyme suppressor. An investigation of MXN's fluorescence behavior in various media and solvents constituted the basis for this new technique. Methanol was shown to enhance the intrinsic fluorescence considerably. After excitation at 610 nm, the highest fluorescence intensity was found at 675 nm. Various experimental parameters, such as media, solvents, and pH levels, were tested and adjusted. ICH (International Conference on Harmonization) guidelines were followed when validating procedures. It was possible to achieve linearity in the 0.02-1.50 µg ml-1 with the method. The sensitivity (in terms of limit of detection and limit of quantification) was 0.003 and 0.008 µg ml-1 , indicating low toxicity. As a result, the current technology has a remarkable recovery for detecting residues in diverse bodily fluids. Also, the quantum yield was estimated for the designed system. Finally, the method was rated by eco-scale scoring.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mitoxantrona / Antineoplásicos Tipo de estudo: Guideline Idioma: En Revista: Luminescence Assunto da revista: BIOFISICA / BIOQUIMICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Egito

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mitoxantrona / Antineoplásicos Tipo de estudo: Guideline Idioma: En Revista: Luminescence Assunto da revista: BIOFISICA / BIOQUIMICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Egito