Your browser doesn't support javascript.
loading
Do we still need to screen our patients?-Orthopaedic scoring based on motion tracking.
Raab, Dominik; Heitzer, Falko; Liaw, Jin Cheng; Müller, Katharina; Weber, Lina; Flores, Francisco Geu; Kecskeméthy, Andrés; Mayer, Constantin; Jäger, Marcus.
Afiliação
  • Raab D; Chair of Mechanics and Robotics, University of Duisburg-Essen, Lotharstraße 1, 47057, Duisburg, Germany. dominik.raab@uni-due.de.
  • Heitzer F; Chair of Orthopaedics and Trauma Surgery, University of Duisburg-Essen, Essen, Germany.
  • Liaw JC; Chair of Mechanics and Robotics, University of Duisburg-Essen, Lotharstraße 1, 47057, Duisburg, Germany.
  • Müller K; Chair of Mechanics and Robotics, University of Duisburg-Essen, Lotharstraße 1, 47057, Duisburg, Germany.
  • Weber L; Chair of Orthopaedics and Trauma Surgery, University of Duisburg-Essen, Essen, Germany.
  • Flores FG; Chair of Mechanics and Robotics, University of Duisburg-Essen, Lotharstraße 1, 47057, Duisburg, Germany.
  • Kecskeméthy A; Chair of Mechanics and Robotics, University of Duisburg-Essen, Lotharstraße 1, 47057, Duisburg, Germany.
  • Mayer C; Department of Orthopaedics, Trauma and Reconstructive Surgery, St. Marien-Hospital Mülheim an der Ruhr, Mülheim an der Ruhr, Germany.
  • Jäger M; Department of Orthopaedics, Trauma and Reconstructive Surgery, St. Marien-Hospital Mülheim an der Ruhr, Mülheim an der Ruhr, Germany.
Int Orthop ; 47(4): 921-928, 2023 04.
Article em En | MEDLINE | ID: mdl-36624129
ABSTRACT

PURPOSE:

Orthopaedic scores are essential for the clinical assessment of movement disorders but require an experienced clinician for the manual scoring. Wearable systems are taking root in the medical field and offer a possibility for the convenient collection of motion tracking data. The purpose of this work is to demonstrate the feasibility of automated orthopaedic scorings based on motion tracking data using the Harris Hip Score and the Knee Society Score as examples.

METHODS:

Seventy-eight patients received a clinical examination and an instrumental gait analysis after hip or knee arthroplasty. Seven hundred forty-four gait features were extracted from each patient's representative gait cycle. For each score, a hierarchical multiple regression analysis was conducted with a subsequent tenfold cross-validation. A data split of 70%/30% was applied for training/testing.

RESULTS:

Both scores can be reproduced with excellent coefficients of determination R2 for training, testing and cross-validation by applying regression models based on four to six features from instrumental gait analysis as well as the patient-reported parameter 'pain' as an offset factor.

CONCLUSION:

Computing established orthopaedic scores based on motion tracking data yields an automated evaluation of a joint function at the hip and knee which is suitable for direct clinical interpretation. In combination with novel technologies for wearable data collection, these computations can support healthcare staff with objective and telemedical applicable scorings for a large number of patients without the need for trained clinicians.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ortopedia / Artroplastia do Joelho Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Int Orthop Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ortopedia / Artroplastia do Joelho Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Int Orthop Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha