Your browser doesn't support javascript.
loading
Interfacial pH measurements during CO2 reduction on gold using a rotating ring-disk electrode.
Liu, Xuan; Monteiro, Mariana C O; Koper, Marc T M.
Afiliação
  • Liu X; Leiden Institute of Chemistry, Leiden University, 2300 RA Leiden, The Netherlands. m.koper@lic.leidenuniv.nl.
  • Monteiro MCO; Leiden Institute of Chemistry, Leiden University, 2300 RA Leiden, The Netherlands. m.koper@lic.leidenuniv.nl.
  • Koper MTM; Leiden Institute of Chemistry, Leiden University, 2300 RA Leiden, The Netherlands. m.koper@lic.leidenuniv.nl.
Phys Chem Chem Phys ; 25(4): 2897-2906, 2023 Jan 27.
Article em En | MEDLINE | ID: mdl-36633182
ABSTRACT
Insights into how to control the activity and selectivity of the electrochemical CO2 reduction reaction are still limited because of insufficient knowledge of the reaction mechanism and kinetics, which is partially due to the lack of information on the interfacial pH, an important parameter for proton-coupled reactions like CO2 reduction. Here, we used a reliable and sensitive pH sensor combined with the rotating ring-disk electrode technique, in which a functionalized Au ring electrode works as a real-time detector of the OH- generated during the CO2 reduction reaction at a gold disk electrode. Variations of the interfacial pH due to both electrochemical and homogeneous reactions are mapped and the correlation of the interfacial pH with these reactions is inferred. The interfacial pH near the disk electrode increases from 7 to 12 with increasing current density, with a sharp increase at around -0.5 V vs. RHE, which indicates a change of the dominant buffering species. Through scan rate-dependent voltammetry and chronopotentiometry experiments, the homogenous reactions are shown to reach equilibrium within the time scale of the pH measurements, so that the interfacial concentrations of different carbonaceous species can be calculated using equilibrium constants. Furthermore, pH measurements were also performed under different conditions to disentangle the relationship between the interfacial pH and other electrolyte effects. The buffer effect of alkali metal cations is confirmed, showing that weakly hydrated cations lead to less pronounced pH gradients. Finally, we probe to which extent increasing mass transport and the electrolyte buffer capacity can aid in suppressing the increase of the interfacial pH, showing that the buffer capacity is the dominant factor in suppressing interfacial pH variations.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Phys Chem Chem Phys Assunto da revista: BIOFISICA / QUIMICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Phys Chem Chem Phys Assunto da revista: BIOFISICA / QUIMICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Holanda