Commutability Assessment of Candidate Reference Materials for Lipoprotein(a) by Comparison of a MS-based Candidate Reference Measurement Procedure with Immunoassays.
Dikaios, Ioannis; Althaus, Harald; Angles-Cano, Eduardo; Ceglarek, Uta; Coassin, Stefan; Cobbaert, Christa M; Delatour, Vincent; Dieplinger, Benjamin; Grimmler, Matthias; Hoofnagle, Andrew N; Kostner, Gerhard M; Kronenberg, Florian; Kuklenyik, Zsusanna; Lyle, Alicia N; Prinzing, Urban; Ruhaak, L Renee; Scharnagl, Hubert; Vesper, Hubert W; Deprez, Liesbet.
Afiliação
  • Dikaios I; European Commission, Joint Research Centre (JRC), Geel, Belgium.
  • Althaus H; Siemens Healthcare Diagnostics Products GmbH, Marburg, Germany.
  • Angles-Cano E; French Institute of Health and Medical Research (INSERM) Université Paris Cité, Paris, France.
  • Ceglarek U; Institute of Laboratory Medicine, Clinical Chemistry and Molecular Diagnostics, University Hospital Leipzig, Leipzig, Germany.
  • Coassin S; LIFE-Leipzig Research Center for Civilization Diseases, University of Leipzig, Leipzig, Germany.
  • Cobbaert CM; Division Clinical Mass Spectrometry of the German Society of Clinical Chemistry and Laboratory Medicine (DGKL), Berlin, Germany.
  • Delatour V; Institute of Genetic Epidemiology, Medical University of Innsbruck, Innsbruck, Austria.
  • Dieplinger B; Department of Clinical Chemistry and Laboratory Medicine, Leiden University Medical Center, Leiden, The Netherlands.
  • Grimmler M; Laboratoire National de Métrologie et d'Essais, Paris, France.
  • Hoofnagle AN; Department of Laboratory Medicine, Konventhospital Barmherzige Brueder Linz and Ordensklinikum Linz Barmherzige Schwestern, Linz, Austria.
  • Kostner GM; DiaSys Diagnostic Systems GmbH, Holzheim, Germany.
  • Kronenberg F; Department of Laboratory Medicine and Pathology, University of Washington, Seattle, USA.
  • Kuklenyik Z; Division of Molecular Biology and Biochemistry, Medical University of Graz, Graz, Austria.
  • Lyle AN; Institute of Genetic Epidemiology, Medical University of Innsbruck, Innsbruck, Austria.
  • Prinzing U; Division of Laboratory Sciences, Centers for Disease Control and Prevention (CDC), Atlanta, USA.
  • Ruhaak LR; Division of Laboratory Sciences, Centers for Disease Control and Prevention (CDC), Atlanta, USA.
  • Scharnagl H; Roche Diagnostics GmbH, Penzberg, Germany.
  • Vesper HW; Department of Clinical Chemistry and Laboratory Medicine, Leiden University Medical Center, Leiden, The Netherlands.
  • Deprez L; Division of Molecular Biology and Biochemistry, Medical University of Graz, Graz, Austria.
Clin Chem ; 69(3): 262-272, 2023 03 01.
Article em En | MEDLINE | ID: mdl-36644921
ABSTRACT

BACKGROUND:

Elevated concentrations of lipoprotein(a) [Lp(a)] are directly related to an increased risk of cardiovascular diseases, making it a relevant biomarker for clinical risk assessment. However, the lack of global standardization of current Lp(a) measurement procedures (MPs) leads to inconsistent patient care. The International Federation for Clinical Chemistry and Laboratory Medicine working group on quantitating apolipoproteins by mass spectrometry (MS) aims to develop a next-generation SI (International system of units)-traceable reference measurement system consisting of a MS-based, peptide-calibrated reference measurement procedure (RMP) and secondary serum-based reference materials (RMs) certified for their apolipoprotein(a) [apo(a)] content. To reach measurement standardization through this new measurement system, 2 essential requirements need to be fulfilled a sufficient correlation among the MPs and appropriate commutability of future serum-based RMs.

METHODS:

The correlation among the candidate RMP (cRMP) and immunoassay-based MPs was assessed by measuring a panel of 39 clinical samples (CS). In addition, the commutability of 14 different candidate RMs was investigated.

RESULTS:

Results of the immunoassay-based MPs and the cRMPs demonstrated good linear correlations for the CS but some significant sample-specific differences were also observed. The results of the commutability study show that RMs based on unspiked human serum pools can be commutable with CS, whereas human pools spiked with recombinant apo(a) show different behavior compared to CS.

CONCLUSIONS:

The results of this study show that unspiked human serum pools are the preferred candidate secondary RMs in the future SI-traceable Lp(a) Reference Measurement System.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Química Clínica / Lipoproteína(a) Tipo de estudo: Risk_factors_studies Limite: Humans Idioma: En Revista: Clin Chem Assunto da revista: QUIMICA CLINICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Química Clínica / Lipoproteína(a) Tipo de estudo: Risk_factors_studies Limite: Humans Idioma: En Revista: Clin Chem Assunto da revista: QUIMICA CLINICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Bélgica