Your browser doesn't support javascript.
loading
Pyrolyzed Ultrasharp Glassy Carbon Microneedles.
Zhou, Chaoqun; Aksit, Aykut; Szeto, Betsy; Li, Richard L; Lalwani, Anil K; Kysar, Jeffrey W.
Afiliação
  • Zhou C; Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
  • Aksit A; Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
  • Szeto B; Department of Otolaryngology - Head & Neck Surgery, Columbia University, New York, NY 10032, USA.
  • Li RL; Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
  • Lalwani AK; Department of Otolaryngology - Head & Neck Surgery, Columbia University, New York, NY 10032, USA.
  • Kysar JW; Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA; Department of Otolaryngology - Head & Neck Surgery, Columbia University, New York, NY 10032, USA.
Adv Eng Mater ; 24(11)2022 Nov.
Article em En | MEDLINE | ID: mdl-36686328
ABSTRACT
Polymeric microneedles fabricated via two-photon polymerization (2PP) lithography enable safe medical access to the inner ear. Herein, the material class for 2PP-lithography-based microneedles is expanded by pyrolyzing 2PP-fabricated polymeric microneedles, resulting in glassy carbon microneedles. During pyrolysis the microneedles shrink up to 81% while maintaining their complex shape when the exposed surface-area-to-volume ratio (SVR) is 0.025 < SVR < 0.04, for the temperature history protocol used herein. The derived glassy carbon is confirmed with energy-dispersive X-ray spectroscopy and Raman spectroscopy. The pyrolyzed glassy carbon has Young's modulus 9.0 GPa. As a brittle material, the strength is stochastic. Using the two-parameter Weibull distribution, the glassy carbon has Weibull modulus of 3.1 and characteristic strength of 710 MPa. The viscoelastic response has characteristic time scale of about 10000 s. In vitro experiments demonstrate that the glassy carbon microneedles introduce controlled perforations across the guinea pig round window membrane (RWM) from the middle ear space into the inner ear, without damaging the microneedle. The resultant controlled perforation of RWM is known to enhance diffusion of therapeutics across the RWM in a predictable fashion. Hence, the glassy carbon microneedles can be deployed for mediating inner ear delivery.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Guideline / Prognostic_studies Idioma: En Revista: Adv Eng Mater Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Guideline / Prognostic_studies Idioma: En Revista: Adv Eng Mater Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos