Your browser doesn't support javascript.
loading
Overcoming the chromatographic challenges when performing LC-MS/MS measurements of pyridoxal-5'-phosphate.
Maus, Anthony; Girtman, Adam; Kiesling, Jessa; Faber, Jennifer; Grebe, Stefan K G.
Afiliação
  • Maus A; Department of Laboratory Medicine and Pathology, Divisions of Clinical Biochemistry and Immunology, Mayo Clinic, Rochester, MN 55905, USA. Electronic address: Maus.anthony@mayo.edu.
  • Girtman A; Department of Laboratory Medicine and Pathology, Divisions of Clinical Biochemistry and Immunology, Mayo Clinic, Rochester, MN 55905, USA.
  • Kiesling J; Department of Laboratory Medicine and Pathology, Divisions of Clinical Biochemistry and Immunology, Mayo Clinic, Rochester, MN 55905, USA.
  • Faber J; Department of Laboratory Medicine and Pathology, Divisions of Clinical Biochemistry and Immunology, Mayo Clinic, Rochester, MN 55905, USA.
  • Grebe SKG; Department of Laboratory Medicine and Pathology, Divisions of Clinical Biochemistry and Immunology, Mayo Clinic, Rochester, MN 55905, USA; Department of Laboratory Medicine and Pathology, Laboratory Genetics and Genomics, Mayo Clinic, Rochester, MN 55905, USA; Department of Medicine, Division of End
Article em En | MEDLINE | ID: mdl-36731354
Pyridoxal-5'-phosphate (PLP), the active form of vitamin B6, is required for numerous enzymatic reactions. Vitamin B6 deficiency or exceptionally high levels of PLP have negative implications, making measurements of PLP imperative for diagnoses and monitoring in many clinical scenarios. Traditional assays are enzymatic, ELISA based, or employ HPLC with various detection modalities; all of these are prone to interferences and crossreactivity with other compounds. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been increasingly used to overcome these issues, but the high polarity of PLP raises chromatographic challenges. Using ion pairing reagents in the mobile phases is a possible solution, but these reagents often have deleterious effects on instrumentation. An alternative strategy is the addition of an ion pairing reagent after extraction, but prior to injection. To prove this, we used 1-octanesulfonic acid (OSA) without changing the LC method or column. With this technique, we observed a 2-4 fold increase in signal-to-noise ratio. Intraday and interday precision of replicate measurements also improved drastically compared to analyses without OSA, while also yielding a dramatic improvement in column life compared to our previous approach and to this point no deleterious effects on instrument hardware commonly associated with traditional ion pairing reagent techniques have been observed.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fosfato de Piridoxal / Cromatografia Líquida / Espectrometria de Massas em Tandem Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fosfato de Piridoxal / Cromatografia Líquida / Espectrometria de Massas em Tandem Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article