Reliability of coracohumeral distance and subcoracoid tendons in subacromial pain syndrome.
Cavaggion, Claudia; Navarro-Ledesma, Santiago; Juul-Kristensen, Birgit; Luque-Suarez, Alejandro; Voogt, Lennard; Struyf, Filip.
Afiliação
  • Cavaggion C; Research Group MOVANT, Department of Rehabilitation Sciences and Physiotherapy, Faculty of Medicine and Health Sciences, University of Antwerp, Campus Drie Eiken, Universiteitsplein 1, 2610, Wilrijk, Belgium.
  • Navarro-Ledesma S; Department of Physiotherapy, University of Granada, Faculty of Health Sciences, Campus of Melilla, Querol Street, 5, 52004, Melilla, Spain. snl@ugr.es.
  • Juul-Kristensen B; Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Campusvej 55, 5230, Odense M, Denmark.
  • Luque-Suarez A; Department of Physiotherapy, Universidad de Malaga, Arquitecto Penalosa S/N, 29002, Malaga, Spain.
  • Voogt L; Instituto de Investigacion Biomedica de Malaga (IBIMA), Dr. Miguel Díaz Recio, 28, 29010, Malaga, Spain.
  • Struyf F; Department of Physical Therapy Studies and Research Centre for Health Care Innovations, Rotterdam University of Applied Sciences, Rochussenstraat 198, 3015EK, Rotterdam, The Netherlands.
Sci Rep ; 13(1): 2383, 2023 02 10.
Article em En | MEDLINE | ID: mdl-36765167
ABSTRACT
This study investigated the intra-rater reliability of a novice ultrasound (US) examiner and the inter-rater reliability of two examiners (novice, expert) in the measures of coracohumeral distance at rest (CHD) and at 60° of elevation without (CHD60) or with weights (CHD60w), tendon thickness of the long head of the biceps (LHB) and subscapularis (SCP). Twenty-one patients with subacromial pain syndrome (SAPS) and 20 asymptomatic participants were included. Intra and inter-rater reliability were tested with intraclass-correlation-coefficient (ICC), differences between raters were analyzed with Bland-Altman plots. Intra-rater reliability for CHD, CHD60 and CHD60w was excellent (ICC = 0.97-0.98) in asymptomatic participants, and good-to-excellent (0.88-0.93) in SAPS, while intra-rater reliability for LHB and SCP was good-to-excellent in asymptomatic participants (0.88-0.97) and in SAPS (0.90-0.92). Inter-rater reliability for CHD, CHD60 and CHD60w was moderate-to-good (0.70-0.90) in asymptomatic participants and good (0.85-0.87) in SAPS, in contrast inter-rater reliability for LHB and SCP was poor in asymptomatic participants (0.10-0.46) and poor-to-moderate (0.49-0.61) in SAPS. Bland-Altman plots revealed systematic and/or proportional bias for tendons' thickness. A novice showed good-to-excellent intra-rater reliability in all US measures, whereas in comparison to an expert a novice can measure reliably CHD, CHD60 and CHD60w, but not LHB and SCP, where more training is recommended.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tendões / Manguito Rotador Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tendões / Manguito Rotador Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Bélgica