Your browser doesn't support javascript.
loading
Patient-specific Monte Carlo-based organ dose estimates in spiral CT via optical 3D body scanning and adaptation of a voxelized phantom dataset: proof-of-principle.
Maddaloni, Francesca Saveria; Sarno, Antonio; Mettivier, Giovanni; Clemente, Stefania; Oliviero, Caterina; Ricciardi, Roberta; Varallo, Antonio; Russo, Paolo.
Afiliação
  • Maddaloni FS; Dipartimento di Fisica 'Ettore Pancini', Università di Napoli Federico II, I-80126 Napoli, Italy.
  • Sarno A; INFN Sezione di Napoli, I-80126 Napoli, Italy.
  • Mettivier G; Dipartimento di Fisica 'Ettore Pancini', Università di Napoli Federico II, I-80126 Napoli, Italy.
  • Clemente S; INFN Sezione di Napoli, I-80126 Napoli, Italy.
  • Oliviero C; Dipartimento di Fisica 'Ettore Pancini', Università di Napoli Federico II, I-80126 Napoli, Italy.
  • Ricciardi R; INFN Sezione di Napoli, I-80126 Napoli, Italy.
  • Varallo A; Azienda Ospedaliera Universitaria Federico II, I-80131 Napoli, Italy.
  • Russo P; Azienda Ospedaliera Universitaria Federico II, I-80131 Napoli, Italy.
Phys Med Biol ; 68(8)2023 04 04.
Article em En | MEDLINE | ID: mdl-36898163
ABSTRACT
Objective. We present a method for personalized organ dose estimates obtained before the computed tomography (CT) exam, via 3D optical body scanning and Monte Carlo (MC) simulations.Approach. A voxelized phantom is derived by adapting a reference phantom to the body size and shape measured with a portable 3D optical scanner, which returns the 3D silhouette of the patient. This was used as an external rigid envelope for incorporating a tailored version of the internal body anatomy derived from a phantom dataset (National Cancer Institute, NIH, USA) matched for gender, age, weight, and height. The proof-of-principle was conducted on adult head phantoms. The Geant4 MC code provided estimates of the organ doses from 3D absorbed dose maps in the voxelized body phantom.Main results. We applied this approach for head CT scanning using an anthropomorphic voxelized head phantom derived from 3D optical scans of manikins. We compared the estimates of head organ doses with those provided by the NCICT 3.0 software (NCI, NIH, USA). Head organ doses differed up to 38% using the proposed personalized estimate and MC code, with respect to corresponding estimates calculated for the standard (non-personalized) reference head phantom. Preliminary application of the MC code to chest CT scans is shown. Real-time pre-exam personalized CT dosimetry is envisaged with adoption of a Graphics Processing Unit-based fast MC code.Significance. The developed procedure for personalized organ dose estimates before the CT exam, introduces a new approach for realistic description of size and shape of patients via voxelized phantoms specific for each patient.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Tomografia Computadorizada Espiral Tipo de estudo: Health_economic_evaluation Limite: Adult / Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Tomografia Computadorizada Espiral Tipo de estudo: Health_economic_evaluation Limite: Adult / Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália