Your browser doesn't support javascript.
loading
Evaluation of the Diagnostic Performance of a SARS-CoV-2 and Influenza A/B Combo Rapid Antigen Test in Respiratory Samples.
Dinç, Harika Öykü; Karabulut, Nuran; Alaçam, Sema; Uysal, Hayriye Kirkoyun; Dasdemir, Ferhat Osman; Önel, Mustafa; Tuyji Tok, Yesim; Sirekbasan, Serhat; Agacfidan, Ali; Gareayaghi, Nesrin; Çakan, Hüseyin; Eryigit, Önder Yüksel; Kocazeybek, Bekir.
Afiliação
  • Dinç HÖ; Department of Pharmaceutical Microbiology, Faculty of Pharmacy, Bezmialem Vakif University, Istanbul 34093, Turkey.
  • Karabulut N; Department of Medical Virology, Basaksehir Çam and Sakura City Hospital, Istanbul 34480, Turkey.
  • Alaçam S; Department of Medical Virology, Basaksehir Çam and Sakura City Hospital, Istanbul 34480, Turkey.
  • Uysal HK; Department of Medical Microbiology, Istanbul Medical Faculty, Istanbul University, Istanbul 34093, Turkey.
  • Dasdemir FO; Department of Medical Microbiology, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Istanbul 34098, Turkey.
  • Önel M; Department of Medical Microbiology, Istanbul Medical Faculty, Istanbul University, Istanbul 34093, Turkey.
  • Tuyji Tok Y; Department of Medical Microbiology, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Istanbul 34098, Turkey.
  • Sirekbasan S; Department of Medical Laboratory, Eldivan Vocational School of Health Services, Techniques Çankiri Karatekin University, Çankiri 18100, Turkey.
  • Agacfidan A; Department of Medical Microbiology, Istanbul Medical Faculty, Istanbul University, Istanbul 34093, Turkey.
  • Gareayaghi N; Blood Center Istanbul Sisli Hamidiye Etfal Training and Research Hospital, Istanbul 34360, Turkey.
  • Çakan H; Department of Biology and Microbiology, Faculty of Arts and Sciences, Çanakkale Onsekiz Mart University, Canakkale 17100, Turkey.
  • Eryigit ÖY; Health Vocational School Anesthesia, Istanbul Health and Technology University, Istanbul 34452, Turkey.
  • Kocazeybek B; Department of Medical Microbiology, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Istanbul 34098, Turkey.
Diagnostics (Basel) ; 13(5)2023 Mar 03.
Article em En | MEDLINE | ID: mdl-36900116
This study aimed to evaluate the performance characteristics of a rapid antigen test developed to detect SARS-CoV-2 (COVID-19), influenza A virus (IAV), and influenza B virus (IBV) (flu) compared with those of the real-time reverse transcription-polymerase chain reaction (rRT-PCR) method. One hundred SARS-CoV-2, one hundred IAV, and twenty-four IBV patients whose diagnoses were confirmed by clinical and laboratory methods were included in the patient group. Seventy-six patients, who were negative for all respiratory tract viruses, were included as the control group. The Panbio™ COVID-19/Flu A&B Rapid Panel test kit was used in the assays. The sensitivity values of the kit were 97.5%, 97.9%, and 33.33% for SARS-CoV-2, IAV, and IBV, respectively, in samples with a viral load below 20 Ct values. The sensitivity values of the kit were 16.7%, 36.5%, and 11.11% for SARS-CoV-2, IAV, and IBV, respectively, in samples with a viral load above 20 Ct. The kit's specificity was 100%. In conclusion, this kit demonstrated high sensitivity to SARS-CoV-2 and IAV for viral loads below 20 Ct values, but the sensitivity values were not compatible with PCR positivity for lower viral loads over 20 Ct values. Rapid antigen tests may be preferred as a routine screening tool in communal environments, especially in symptomatic individuals, when diagnosing SARS-CoV-2, IAV, and IBV with high caution.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Diagnostics (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Diagnostics (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Turquia