Your browser doesn't support javascript.
loading
Ultrasensitive fluorescence detection of multiple DNA methyltransferases based on DNA walkers and hyperbranched rolling circle amplification.
Zhang, Siqi; Shao, Huahao; Li, Kai-Bin; Shi, Wei; Wang, Yichao; Han, De-Man; Mo, Jinggang.
Afiliação
  • Zhang S; Department of Hepatobiliary Surgery, Taizhou Central Hospital (Taizhou University Hospital), Taizhou University, Jiaojiang, Zhejiang, 318000, China; School of Pharmaceutical and Chemical Engineering, Taizhou University, Jiaojiang, Zhejiang, 318000, China.
  • Shao H; Zhijiang College of Zhejiang University of Technology, Shaoxing, Zhejiang, 312000, China.
  • Li KB; School of Pharmaceutical and Chemical Engineering, Taizhou University, Jiaojiang, Zhejiang, 318000, China.
  • Shi W; School of Pharmaceutical and Chemical Engineering, Taizhou University, Jiaojiang, Zhejiang, 318000, China.
  • Wang Y; Department of Hepatobiliary Surgery, Taizhou Central Hospital (Taizhou University Hospital), Taizhou University, Jiaojiang, Zhejiang, 318000, China. Electronic address: wangyichaobei@126.com.
  • Han DM; School of Pharmaceutical and Chemical Engineering, Taizhou University, Jiaojiang, Zhejiang, 318000, China. Electronic address: hdmtzc@126.com.
  • Mo J; Department of Hepatobiliary Surgery, Taizhou Central Hospital (Taizhou University Hospital), Taizhou University, Jiaojiang, Zhejiang, 318000, China. Electronic address: mjg8882@126.com.
Anal Chim Acta ; 1252: 341057, 2023 Apr 29.
Article em En | MEDLINE | ID: mdl-36935155
The accurate and ultrasensitive detection of multiple methyltransferases was in great request for clinical diagnosis and epigenetic therapy. Here, a novel fluorescence assay was proposed for ultrasensitive CpG methyltransferase (M.SssI) and DNA adenine methyltransferase (Dam) activity detection based on hyperbranched rolling circle amplification (HRCA) and DNA walkers. The biosensor showed an extremely high sensitivity due to the dual-amplification strategy of HRCA and DNA walker. The LOD of the biosensor for M.SssI and Dam methyltransferase was estimated at 0.0004 U/mL and 0.001 U/mL, respectively. Without the presence of M.SssI methyltransferase, the corresponding recognition site of hairpin HM was cleaved by HpaII endonuclease, generating a DNA fragment (T-DNA) and inducing the DNA walker-HRCA reaction. Since the HRCA products contained numerous double-strand DNA (dsDNA), SYBR Green I could be embedded in the dsDNA, leading to a high fluorescent signal. In the presence of M.SssI methyltransferase, the corresponding recognition site of hairpin HM was methylated and the HpaII endonuclease-catalyzed stem of hairpin HM dissociation was hindered, leading to no DNA fragment (T-DNA) present. Hence, the DNA walker-HRCA reaction was not initiated and the fluorescent signal of SYBR Green I remained at a low level. Similarly, DNA adenine methyltransferase (Dam) and its inhibitors could also be detected by redesigning hairpin HD with the Dam recognition sequences. Furthermore, the sensing system was applied to analyze the endogenic Dam methyltransferase in the real samples such as E. coli cell lysate.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Escherichia coli Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Escherichia coli Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China