Your browser doesn't support javascript.
loading
Placental micro blood perfusion for isolated single umbilical artery foetuses and VEGF protein expression in the placenta.
Li, Tian-Gang; Tie, Hong-Xia; Qi, Ping-An; Lv, Ling.
Afiliação
  • Li TG; Department of Ultrasound Diagnosis, Gansu Provincial Maternity and Child-care Hospital, Lanzhou, Gansu Province, P. R. China.
  • Tie HX; Department of Ultrasound Diagnosis, Gansu Provincial Maternity and Child-care Hospital, Lanzhou, Gansu Province, P. R. China.
  • Qi PA; Department of Ultrasound Diagnosis, Gansu Provincial Maternity and Child-care Hospital, Lanzhou, Gansu Province, P. R. China.
  • Lv L; Department of Obstetrics, Gansu Provincial Maternity and Child-care Hospital, Lanzhou, Gansu Province, P. R. China.
J Obstet Gynaecol ; 43(1): 2189480, 2023 Dec.
Article em En | MEDLINE | ID: mdl-37010954
ABSTRACT
Microblood perfusion of isolated single umbilical artery (ISUA) foetus placenta was evaluated using three-dimensional power Doppler ultrasound (3D-PDU). Vascular endothelial growth factor (VEGF) protein expression in the placenta was also semi-quantitative and qualitatively analysed. Differences between ISUA and control groups were compared. 3D-PDU was used to detect placental blood flow parameters, including vascularity index (VI), flow index, and vascularity flow index (VFI), in 58 foetuses in the ISUA group and 77 normal foetuses in the control group. Immunohistochemistry and polymerase chain reaction were employed to analyse the VEGF expression in placental tissues of 26 foetuses in the ISUA group and 26 foetuses in the control group. The control group exhibited higher VI and VFI than the ISUA group (p < 0.05). Meanwhile, the ISUA group showed a higher positivity rate of VEGF protein expression than the control group (χ2=28.013, p˂0.001). The ISUA group also presented a higher VEGF mRNA protein expression than the control group (p˂0.001). 3D-PDU can be used to quantitatively analyse microblood perfusion of the placenta and provide an objective assessment of ISUA foetuses.Impact statementWhat is already known on this subject? Colour Doppler flow can be used to evaluate placental and maternal circulation and remains an ideal method for evaluating high-risk placental function. Three-dimensional power Doppler ultrasound (3D-PDU) can be used to quantify blood vessels and blood flow in placental parenchyma via the measurement of the amplitude of blood vessels and blood flow in normal foetuses, respectively.What do the results of this study add? 3D-PDU can be used to quantitatively analyse micro blood perfusion of the placenta and conduct an objective assessment of isolated single umbilical artery foetuses. The isolated single umbilical artery foetuses exhibited a higher positivity rate of vascular endothelial growth factor (VEGF) protein expression and higher VEGF mRNA protein expression than the normal foetuses.What are the implication of these findings for clinical practice and/or further research? The study provides a reliable basis for maternal-foetal monitoring during pregnancy in the isolated single umbilical artery foetuses. Objective assessment of the occurrence and development of foetuses with isolated single umbilical artery was performed.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Placenta / Artéria Umbilical Única Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: J Obstet Gynaecol Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Placenta / Artéria Umbilical Única Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: J Obstet Gynaecol Ano de publicação: 2023 Tipo de documento: Article