Your browser doesn't support javascript.
loading
Rapid and inexpensive voltammetric detection of ochratoxin A in wheat matrices.
Arteshi, Yaser; Lima, Dhésmon; Tittlemier, Sheryl A; Kuss, Sabine.
Afiliação
  • Arteshi Y; Department of Chemistry, University of Manitoba, 144, Dysart Road, R3T 2N2 Winnipeg, MB, Canada. Electronic address: arteshiy@myumanitoba.ca.
  • Lima D; Department of Chemistry, University of Manitoba, 144, Dysart Road, R3T 2N2 Winnipeg, MB, Canada. Electronic address: dhesmon.lima@umanitoba.ca.
  • Tittlemier SA; Canadian Grain Commission, 303, Main Street, R3C 3G8, Winnipeg, MB, Canada. Electronic address: sheryl.tittlemier@grainscanada.gc.ca.
  • Kuss S; Department of Chemistry, University of Manitoba, 144, Dysart Road, R3T 2N2 Winnipeg, MB, Canada. Electronic address: sabine.kuss@umanitoba.ca.
Bioelectrochemistry ; 152: 108451, 2023 Aug.
Article em En | MEDLINE | ID: mdl-37150089
Produced as toxic metabolites by fungi, mycotoxins, such as ochratoxin A (OTA), contaminate grain and animal feed and cause great economic losses. Herein, we report the fabrication of an electrochemical sensor consisting of an inexpensive and label-free carbon black-graphite paste electrode (CB-G-CPE), which was fully optimized to detect OTA in durum wheat matrices using differential pulse voltammetry (DPV). The effect of carbon paste composition, electrolyte pH and DPV parameters were studied to determine the optimum conditions for the electroanalytical determination of OTA. Full factorial and central composite experimental designs (FFD and CCD) were used to optimize DPV parameters, namely pulse width, pulse height, step height and step time. The developed electrochemical sensor successfully detected OTA with detection and quantification limits equal to 57.2 nM (0.023 µg mL-1) and 190.6 nM (0.077 µg mL-1), respectively. The accuracy and precision of the presented CB-G-CPE was used to successfully quantify OTA in real wheat matrices. This study presents an inexpensive and user-friendly method with potential applications in grain quality control.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Triticum / Grafite Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Bioelectrochemistry Assunto da revista: BIOQUIMICA Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Triticum / Grafite Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Bioelectrochemistry Assunto da revista: BIOQUIMICA Ano de publicação: 2023 Tipo de documento: Article