Your browser doesn't support javascript.
loading
Dual-energy CT iodine overlay improves efficiency of oral contrast leak assessment.
Hinen, Shaun P; Griffith, Joseph P; Chamberlin, Jordan; Waltz, Jeffrey; Kocher, Madison; Krull, Veronica; Young, Tristan; Litvin, Cara B; Varga-Szemes, Akos; Hardie, Andrew D.
Afiliação
  • Hinen SP; Department of Radiology and Radiological Sciences, The Medical University of South Carolina, Charleston, SC, USA.
  • Griffith JP; Department of Radiology and Radiological Sciences, The Medical University of South Carolina, Charleston, SC, USA.
  • Chamberlin J; Department of Radiology and Radiological Sciences, The Medical University of South Carolina, Charleston, SC, USA.
  • Waltz J; Department of Radiology and Radiological Sciences, The Medical University of South Carolina, Charleston, SC, USA.
  • Kocher M; Department of Radiology and Radiological Sciences, The Medical University of South Carolina, Charleston, SC, USA.
  • Krull V; Department of Radiology and Radiological Sciences, The Medical University of South Carolina, Charleston, SC, USA.
  • Young T; Department of Radiology and Radiological Sciences, The Medical University of South Carolina, Charleston, SC, USA.
  • Litvin CB; Department of Radiology and Radiological Sciences, The Medical University of South Carolina, Charleston, SC, USA.
  • Varga-Szemes A; Department of Radiology and Radiological Sciences, The Medical University of South Carolina, Charleston, SC, USA.
  • Hardie AD; Department of Radiology and Radiological Sciences, The Medical University of South Carolina, Charleston, SC, USA.
Acta Radiol ; 64(8): 2357-2362, 2023 Aug.
Article em En | MEDLINE | ID: mdl-37157189
ABSTRACT

BACKGROUND:

Evaluation for gastrointestinal leak is a frequent imaging indication, and dual-energy computed tomography (DECT) with oral or rectally administered contrast can be used to improve efficiency and diagnostic confidence.

PURPOSE:

To assess the value of the DECT iodine overlay (IO) reconstruction as a stand-alone image set compared to routine CT in assessing oral or rectal contrast leak from the gastrointestinal system. MATERIAL AND

METHODS:

A blinded, retrospective audit study was performed by three readers who each interpreted 50 studies performed for assessment of oral or rectal contrast leak that were acquired using DECT. Each reader independently assessed both the routine CT images and the images of the reconstructed IO for contrast leak in random order with a six-week "wash-out period" between readings. Clinical follow-up provided the reference standard. Readers recorded the presence/absence of a leak, diagnostic confidence, image quality score, and interpretation time for each image set.

RESULTS:

Pooled data for overall accuracy in identification of a leak increased from 0.81 (95% confidence interval [CI]=0.74-0.87) for routine CT to 0.91 (95% CI=0.85-0.95) with IO, and the area under the curve (AUC) was significantly higher for IO than routine CT (P = 0.015). Readers required significantly less time to interpret IO than routine CT (median improvement of 12.5 s per image using pooled data; P < 0.001) while maintaining diagnostic confidence and perceived image quality.

CONCLUSION:

Use of DECT IO reconstructions for identification of oral or rectal contrast leak requires less time to interpret than routine CT with improved accuracy and maintained diagnostic confidence and perceived image quality.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Iodo Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Acta Radiol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Iodo Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Acta Radiol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos