Your browser doesn't support javascript.
loading
Fractal analysis of the macular region in healthy eyes using swept-source optical coherence tomography angiography.
Magesan, Kowsigan; Gnanaraj, Ramya; Tojjar, Jasaman; Amose, T; Alagorie, Ahmed Roshdy; Mahalingam, Maanasi; Sen, Parveen; Verma, Aditya; Sadda, SriniVas R.
Afiliação
  • Magesan K; Elite School of Optometry, Unit of Medical Research Foundation, Chennai, Tamil Nadu, India.
  • Gnanaraj R; Shri Bhagwan Mahavir Vitreoretinal Services, Medical Research Foundation, Chennai, Tamil Nadu, India.
  • Tojjar J; Shri Bhagwan Mahavir Vitreoretinal Services, Medical Research Foundation, Chennai, Tamil Nadu, India.
  • Amose T; Doheny Eye Institute, Pasadena, CA, USA.
  • Alagorie AR; Doheny Eye Institute, Pasadena, CA, USA.
  • Mahalingam M; Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, 150 N, Orange Grove Blvd, Pasadena, CA, 91103, USA.
  • Sen P; Elite School of Optometry, Unit of Medical Research Foundation, Chennai, Tamil Nadu, India.
  • Verma A; Shri Bhagwan Mahavir Vitreoretinal Services, Medical Research Foundation, Chennai, Tamil Nadu, India.
  • Sadda SR; Department of Ophthalmology, Faculty of Medicine, Tanta University, Tanta, Egypt.
Graefes Arch Clin Exp Ophthalmol ; 261(10): 2787-2794, 2023 Oct.
Article em En | MEDLINE | ID: mdl-37199803
ABSTRACT

PURPOSE:

This cross-sectional observational study evaluated the relationship between retinal vascular fractal dimension (FD) and age, as well as other vascular parameters in healthy eyes using swept-source optical coherence tomography angiography (SS-OCTA).

METHODS:

The study cohort consisted of 222 eyes of 116 healthy participants with no ocular or systemic disease. SS-OCTA images were captured and analyzed using the Plex Elite 9000 and software tools available in the advanced retinal imaging (ARI) network hub. The retinal vascular layers were defined by the instrument's automatic retinal layer segmentation. The fractal analysis was performed on the superficial capillary plexus (SCP), deep capillary plexus (DCP), and the whole retina. Grayscale OCTA images were standardized and binarized using ImageJ and fractal box-counting analyses were performed using Fractalyse software. Pearson's correlation was used to analyze the correlation between FD and retinal vascular parameters.

RESULTS:

The results showed that FD values were significantly higher in the 6 mm ring and the whole 6 × 6 scan region when compared to the 1 mm ETDRS central subfield. The correlation between age and FD was weak with a significant positive correlation between age and FD of the SCP in the 6 mm ring and between age and FD of the DCP in the 1 mm ring. Overall, differences in FD values in these healthy eyes were extremely small regardless of age or macular location.

CONCLUSION:

FD values in normal eyes show little variation with age and are relatively stable across the macula. This suggests that FD values may not need adjustment for age or location when evaluated in the context of retinal disease.