Your browser doesn't support javascript.
loading
Concurrent and discriminant validity and reliability of an Android App to assess time, velocity and power during sit-to-stand test in community-dwelling older adults.
Ruiz-Cárdenas, Juan D; Montemurro, Alessio; Del Mar Martínez-García, María; Rodríguez-Juan, Juan J.
Afiliação
  • Ruiz-Cárdenas JD; Physiotherapy Department, Faculty of Physiotherapy, Podiatry and Occupational Therapy, Universidad Católica de Murcia, Av. de los Jerónimos, 135, Guadalupe de Maciascoque, 30107, Murcia, Spain. jdruiz@ucam.edu.
  • Montemurro A; Physiotherapy Department, Faculty of Physiotherapy, Podiatry and Occupational Therapy, Universidad Católica de Murcia, Av. de los Jerónimos, 135, Guadalupe de Maciascoque, 30107, Murcia, Spain.
  • Del Mar Martínez-García M; Physiotherapy Department, Faculty of Physiotherapy, Podiatry and Occupational Therapy, Universidad Católica de Murcia, Av. de los Jerónimos, 135, Guadalupe de Maciascoque, 30107, Murcia, Spain.
  • Rodríguez-Juan JJ; Cystic Fibrosis Association of Murcia, Av. de Las Palmeras, 37, 30120, Murcia, Spain.
Aging Clin Exp Res ; 35(8): 1631-1640, 2023 Aug.
Article em En | MEDLINE | ID: mdl-37306926
ABSTRACT

INTRODUCTION:

Nowadays, smartphones are equipped with the most sophisticated hardware which provides the opportunity to develop specific smartphone apps to analyze kinetic and kinematic parameters during sit-to-stand test in a clinical setting. The aims were to ascertain whether a new Android video-analysis based-App is comparable to the previously validated Apple-App for measuring time, velocity and power during sit-to-stand test, to determine its reliability and discriminant validity.

METHODS:

One-hundred sixty-one older adults (61-86 years) were recruited from an elderly social center. Sit-to-stand variables were simultaneously recorded through the Android and Apple-App. Their validity and inter-rater, intra-rater, and test-retest reliability was tested using an intraclass correlation coefficient (ICC2-1). Low gait speed (< 1.0 m/s), low physical performance (Short Physical Performance Battery < 10 points), and sarcopenia (EWGSOP2 guideline) were used to determine discriminant validity which was reported as the area under the curves (AUC) and their effect sizes (Hedges' g) for independent sample t-test.

RESULTS:

Excellent reproducibility (ICC2-1 > 0.85) and strong agreement (ICC2-1 > 0.90) between operating systems for sit-to-stand variables derived from the App was found. Older adults classified as sarcopenic (11.2%), low physical performance (15.5%), or reduced gait speed (14.3%) showed worse sit-to-stand time, velocity and power with large effect sizes (Hedges' g > 0.8) compared to their respective counterpart. These variables showed the acceptable-to-excellent ability to identify low gait speed, low physical performance, and sarcopenic older adults (AUC-range 0.73-0.82).

CONCLUSION:

The new Sit-to-Stand App running on the Android operating system is comparable to the previously validated Apple App. Excellent reproducibility and acceptable-to-excellent discriminant validity were found.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sarcopenia / Aplicativos Móveis Tipo de estudo: Guideline / Prognostic_studies Limite: Aged / Humans Idioma: En Revista: Aging Clin Exp Res Assunto da revista: GERIATRIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sarcopenia / Aplicativos Móveis Tipo de estudo: Guideline / Prognostic_studies Limite: Aged / Humans Idioma: En Revista: Aging Clin Exp Res Assunto da revista: GERIATRIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Espanha