Your browser doesn't support javascript.
loading
Assessment of lung doses in patients undergoing total body irradiation for haematological malignancies with and without lung shielding.
Lonski, Peta; MacManus, Michael; Campbell, Belinda A; Wheeler, Greg; Ungureanu, Elena; Kron, Tomas.
Afiliação
  • Lonski P; Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
  • MacManus M; Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
  • Campbell BA; Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
  • Wheeler G; Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
  • Ungureanu E; Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
  • Kron T; Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
J Med Imaging Radiat Oncol ; 67(6): 684-690, 2023 Sep.
Article em En | MEDLINE | ID: mdl-37343142
ABSTRACT

INTRODUCTION:

Total body irradiation (TBI) practices vary considerably amongst centres, and the risk of treatment related toxicities remains unclear. We report lung doses for 142 TBI patients who underwent either standing TBI with lung shield blocks or lying TBI without blocks.

METHODS:

Lung doses were calculated for 142 TBI patients treated between June 2016 and June 2021. Patients were planned using Eclipse (Varian Medical Systems) using AAA_15.6.06 for photon dose calculations and EMC_15.6.06 for electron chest wall boost fields. Mean and maximum lung doses were calculated.

RESULTS:

Thirty-seven patients (26.2%) were treated standing using lung shielding blocks with 104 (73.8%) treated lying down. Lowest relative mean lung doses were achieved using lung shielding blocks in standing TBI, reducing the mean lung doses to 75.2% of prescription (9.9 Gy), ±4.1% (range 68.6-84.1%) for a prescribed dose of 13.2 Gy in 11 fractions, including contributions from electron chest wall boost fields, compared to 12 Gy in 6 fraction lying TBI receiving 101.6% mean lung dose (12.2 Gy) ±2.4% (range 95.2-109.5%) (P ≪ 0.05). Patients treated lying down with 2 Gy single fraction received the highest relative mean lung dose on average, with 108.4% (2.2 Gy) ±2.6% of prescription (range 103.2-114.4%).

CONCLUSION:

Lung doses have been reported for 142 TBI patients using the lying and standing techniques described herein. Lung shielding blocks significantly reduced mean lung doses despite the addition of electron boost fields to the chest wall.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Irradiação Corporal Total / Neoplasias Hematológicas Tipo de estudo: Etiology_studies Limite: Humans Idioma: En Revista: J Med Imaging Radiat Oncol Assunto da revista: DIAGNOSTICO POR IMAGEM / NEOPLASIAS / RADIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Irradiação Corporal Total / Neoplasias Hematológicas Tipo de estudo: Etiology_studies Limite: Humans Idioma: En Revista: J Med Imaging Radiat Oncol Assunto da revista: DIAGNOSTICO POR IMAGEM / NEOPLASIAS / RADIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Austrália