Your browser doesn't support javascript.
loading
Evaluation and assessment of clique arrangements for the estimation of omnipolar electrograms in high density electrode arrays: an experimental animal model study.
Ruipérez-Campillo, Samuel; Crespo, Marina; Tormos, Álvaro; Guill, Antonio; Cebrián, Antonio; Alberola, Antonio; Heimer, Jakob; Chorro, Francisco J; Millet, José; Castells, Francisco.
Afiliação
  • Ruipérez-Campillo S; ITACA Institute, Universitat Politècnica de València, Valencia, Spain. saruicam@upv.edu.es.
  • Crespo M; Department of Information Technology and Electrical Engineering, Swiss Federal Institute of Technology (ETH), Zürich, Switzerland. saruicam@upv.edu.es.
  • Tormos Á; School of Medicine, Stanford University, Stanford, CA, USA. saruicam@upv.edu.es.
  • Guill A; ITACA Institute, Universitat Politècnica de València, Valencia, Spain.
  • Cebrián A; ITACA Institute, Universitat Politècnica de València, Valencia, Spain.
  • Alberola A; ITACA Institute, Universitat Politècnica de València, Valencia, Spain.
  • Heimer J; ITACA Institute, Universitat Politècnica de València, Valencia, Spain.
  • Chorro FJ; Departamento de Fisiología, Universitat de València, Valencia, Spain.
  • Millet J; Centro de Investigación Biomédica en Red Enfermedades Cardiovascular (CIBERCV), Madrid, Spain.
  • Castells F; Department of Mathematics, Seminar for Statistics, Swiss Federal Institute of Technology (ETH), Zürich, Switzerland.
Phys Eng Sci Med ; 46(3): 1193-1204, 2023 Sep.
Article em En | MEDLINE | ID: mdl-37358782
ABSTRACT
High-density catheters combined with Orientation Independent Sensing (OIS) methods have emerged as a groundbreaking technology for cardiac substrate characterisation. In this study, we aim to assess the arrangements and constraints to reliably estimate the so-called omnipolar electrogram (oEGM). Performance was evaluated using an experimental animal model. Thirty-eight recordings from nine retrospective experiments on isolated perfused rabbit hearts with an epicardial HD multielectrode were used. We estimated oEGMs according to the classic triangular clique (4 possible orientations) and a novel cross-orientation clique arrangement. Furthermore, we tested the effects of interelectrode spacing from 1 to 4 mm. Performance was evaluated by means of several parameters that measured amplitude rejection ratios, electric field loop area, activation pulse width and morphology distortion. Most reliable oEGM estimations were obtained with cross-configurations and interelectrode spacings [Formula see text] mm. Estimations from triangular cliques resulted in wider electric field loops and unreliable detection of the direction of the propagation wavefront. Moreover, increasing interelectrode distance resulted in increased pulse width and morphology distortion. The results prove that current oEGM estimation techniques are insufficiently accurate. This study opens a new standpoint for the design of new-generation HD catheters and mapping software.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Software / Coração Tipo de estudo: Observational_studies Limite: Animals Idioma: En Revista: Phys Eng Sci Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Software / Coração Tipo de estudo: Observational_studies Limite: Animals Idioma: En Revista: Phys Eng Sci Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Espanha