Your browser doesn't support javascript.
loading
Determination of the Attenuation Coefficients of Epoxy Resin with Carbopol Polymer as a Breast Phantom Material at Low Photon Energy Range.
Marashdeh, Mohammad; Abdulkarim, Muthanna.
Afiliação
  • Marashdeh M; Department of Physics, College of Sciences, Imam Mohammad Ibn Saud Islamic University (IMSIU), P.O. Box 90950, Riyadh 11623, Saudi Arabia.
  • Abdulkarim M; Department of Pharmaceutical Sciences, College of Pharmacy, Alfaisal University, P.O. Box 50927, Riyadh 11533, Saudi Arabia.
Polymers (Basel) ; 15(12)2023 Jun 11.
Article em En | MEDLINE | ID: mdl-37376291
ABSTRACT
Six different composites of epoxy resin and Carbopol 974p polymer were prepared based on Carbopol 974p polymer concentrations of 0%, 5%, 10%, 15%, 20%, and 25%. The linear and mass attenuation coefficients, Half Value Layer (HVL), and mean free path (MFP) of these composites were determined using single-beam photon transmission in the energy range between 16.65 keV and 25.21 keV. This was carried out by determining the attenuation of ka1 X-ray fluorescent (XRF) photons from niobium, molybdenum, palladium, silver, and tin targets. The results were compared with theoretical values of three types of breast material (Breast 1, Breast 2, Breast 3) and Perspex, which was calculated using a XCOM computer program. The results show that there were no significant differences in the attenuation coefficient values after the consequent Carbopol additions. Moreover, it was found that the mass attenuation coefficients of all tested composites were close to those of Perspex and the values for Breast 3. The HVL and MFP results showed that the E25 sample is closer to the results of the Perspex material with differences of (0.53-1.15%) and (0.51-1.20%), respectively. In addition, the densities of the fabricated samples were in the range of 1.102-1.170 g/cm3, which is in the range of human breast density. A computed tomography (CT) scanner was used to investigate the CT number values for the fabricated samples. The CT numbers of all samples were in the range of human breast tissue (24.53-40.28 HU). Based on these findings, the fabricated epoxy-Carbopol polymer is a good candidate for use as a breast phantom material.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Polymers (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Arábia Saudita